background image

45

The 

mask

 glasses shall be worn by all persons who are present 

when flashes are administered, for better visual comfort. They form 
a boundary to the area where the application of flash treatment is 

prohibited (e.g. eyelashes, eyebrows, etc.)

USING THE    ACCESSORIES

The 

o p t i c

 cartridge has a pre-

programmed ser vice life, which 

guarantees a consistent quality of 

light emissions, from the first to the 

last available flash. It is supplied with 

its associated activation card (only for 

C

). The 

optic

 cartridge (and its 

activation card) must be replaced when 

the number of flashes has been 

exhausted.

The 

gel

 used for flash treatment must be stored at ambient 

temperature. It is used in a thick layer, and is applied 

progressively as the session proceeds, in order to prevent 

drying-out on the skin. Once 

gel

 has been applied to the 

skin and exposed to flash treatment it must not, under any 

circumstances, be recovered and applied to another 

zone. Repeated exposure to flash treatment is liable 

to change its optical characteristics. At the end of 

the session, it must be removed from the surface 

of the skin using a damp towel, or under the 

shower. Remove 

gel

 from the optical parts of the 

mobile head of the applicator using a damp towel, 
then apply the 

clean

 spray.

Active Ingredients:

Methylisothiazolinone and Methylchloroisothiazolinone (MCI/MI). 

Their quantity, in regards to the 3:1 ratio, is 0.0008 %. Does not any 

contain formic aldehyde. Keep away from light - External use only. 

Do not use on injured, burnt or infected skin.

The 

stop

  plate  is  constructed  of  a  flash-resistant  material.  It  is 

used to mask an area where flash treatment is not to be applied (for 

example, tattoos). The glass end of the applicator (optical guide) 
may also be positioned to overlap the 

stop

 plate and the skin.

The 

extractor

 tool is used to separate the mobile head of your 

applicator for the cleaning of the optical parts or the replacement 

of the cartridge.

The self-adhesive 

patches

, supplied in strips of 220, are used to 

mask  small areas which are not to receive flash treatment (such as 

beauty spots). They must be applied after shaving and prior to the 
application of the 

gel

. It is then possible to apply flash treatment to 

the entire area without worrying about beauty spots. The 

patches

 

are removed at the end of the session.

The 

fun

 

stencils are used to mark out zones which are not to receive 

flash treatment, allowing localized hair growth to be retained in fun 

shapes. They are to be applied after the complete shaving of the area 
and the application of 

gel

. The presence of 

gel

 will retain the patches 

in position, to a degree. It is possible for flash treatment to overlap  the 

edge of these stencils, in order to ensure the clear demarcation of the 
outlines of the shape required.

Made in France

Made in China

Made in China

Made in France

Made in France

Made in France

Made in France

Made in Europe

You can find all these products on our online         shop

 prostore.esw-beauty.com

 

FUN

(option)

OPTIC

gel

mask

stop

clean

extractor

patches

 

SPECIAL FILTER

The 

special filter

 is designed for highly pigmented skins. It is 

supplied in an individual plastic casing.

The 

pen

 is used to mark out the area to be depilated. The work 

pencil must be used before the 

gel

 is applied.

IMPORTANT NOTE:

 Only the 

pen

 

pencil must be used to mark out 

the areas which are to receive flash treatment. It has been tested 
for the absence of reaction to flashes. Any other pencil may cause 
skin burns when the flash is applied to the line drawn on the skin.

Made in China

pen

The 

clean

 spray is used to clean and maintain:

•  The optical parts of the mobile head of the applicator:

- External optical parts: spray directly and wipe with a dry 

cotton cloth.

- Internal optical parts: Never spray directly onto the internal 

optical parts. Apply the spray to a dry cotton cloth, then clean 

the filter (the flat element of red-coloured glass) using this 

impregnated cloth. Complete the cleaning using a dry part 

of the cloth.

•  The touch screen of the device: Never spray directly onto the 

touch screen. Apply the spray to a dry cloth, then clean the 

touch screen using this impregnated cloth. Complete the 

cleaning using a dry part of the cloth.

The spray must not be used until 
the device has been unplugged and 
the optical parts have cooled. If any 
operation is to be undertaken after 
using 

, you must wait until the 

fan in the applicator has shut down  
completely before unplugging the 
base. Amongst other functions, this 
will ensure the correct cooling of the 
optical components. 

44

Содержание E-O75

Страница 1: ...User Manual...

Страница 2: ...ll see is an exceptional product I hope that you will be completely satisfied with your device and that you will share your experience on our company s official website prostore esw beauty com Yours S...

Страница 3: ...V delivered in its own plastic case REMINDER Only E Swin is entitled to market and its accessories optic stop clean patches pen gel mask fun etc on the shop prostore esw beauty com PACKAGE CONTENTS W...

Страница 4: ...manufacturer When using the device make sure to place it on a flat surface in a place where all risk of falls will be avoided E Swin SAS disclaims any responsibility for any damage resulting from imp...

Страница 5: ...ore starting a session the patient must not apply any cosmetic treatments which are aggressive to the skin In the case of non aggressive cosmetic treatments however a time interval of 24 hours should...

Страница 6: ...system is used y METHODE OF TREATMENT BEFORE THE SESSION Explain the technology and the principle of depilation to the patient Identify any contra indication for the use of pulsed light Specify the co...

Страница 7: ...y for devices Applicator holding area Vizor to protect touchscreen Mobile head Release clips for the mobile head Mobile head Applicator zone Applicator zone Air vents Trigger button Flash ready indica...

Страница 8: ...ght energy desired 17 Set of all precautions to observe imperatively before each use 18 Pause icon to pause the flashing session Pressing this icon puts in pause mode This mode prohibits the applicato...

Страница 9: ......

Страница 10: ...ustbeflatandregular It must be clean and dust free For better efficiency of it is recommended to clean the filter before every use with the spray clean that is provided when you purchase Any damaged f...

Страница 11: ...hese codes will no longer be requested 2 CARTRIDGE CODES You own a Cartridge codes 5 characters followed by another set of 5 characters must be entered each time you renew the optic cartridge These co...

Страница 12: ...can treat your patient with Depilatory cream You can only treat your patient with 1 week after their last depilatory cream treatment Waxing electric epilator tweezers You can only treat your patient w...

Страница 13: ...skin when the flash is delivered Increased potential rashes or burns on highly pigmented skins olive after a session IMPORTANT Thedarkertheskiniswhetherbynatureorafteratan themoreyouhavetobecareful ab...

Страница 14: ...use stop to cover a rather large area that must be flashed tattoos REMINDER Make sure that you are applying a thick layer of gel The gel must never overflowinsidethemobileheadofthedevice When selectin...

Страница 15: ...tor optical guide must be applied on the skin Then press in order to clip the head of the applicator Take care of stretching the skin where it is the thinnest so that the glass tip optical guide of th...

Страница 16: ......

Страница 17: ...ut the cartridge delicately and remove it completely image G A 0 6 Consumables Configuration NOTE Unlike the fans located inside the applicator that stop running after a certain period fans located in...

Страница 18: ...as it may create serious damage to your device You must return the damaged cartridge to us and order another one Check the cartridge has been well engaged y STEP 6 CLEANING EXTERNAL AND INTERNAL OPTI...

Страница 19: ...rocedure please refer strictly to the instructions given by our technical department y STEP 9 ONLY FOR IN THIS CASE IT IS COMPULSORY TO ENTER ACTIVATION CODES FOR THE OPTIC CARTRIDGE Plug in and turn...

Страница 20: ...ss your personal space byclickingonyournameonthetoprightofthepageandclickingon Youraccount ClickonTrainingquestionsandActivation codes You will then see your E Swin products Click on the blue box Acti...

Страница 21: ...ANGUAGE SELECTION screen D Press on the flag corresponding to the requested language The message Language has been switched is displayed you must then press OK for the change to become effective The L...

Страница 22: ...ptic car tridge is dismounted only touch the plastic parts and definitely not the electrodes the tube or the reflector Never try touching the contact elements Never attempt to dismount the applicator...

Страница 23: ...is then possible to apply flash treatment to the entire area without worrying about beauty spots The patches are removed at the end of the session The fun stencils are used to mark out zones which are...

Страница 24: ...tor BODY OF THE APPLICATOR Clean all of the plastic parts of the applicator with a clean cloth which has been dampened with water without any additives y BASE CABLE TO APPLICATOR Thiscablemustalwaysst...

Страница 25: ...SECU02 No cartridge detected The device doesn t work Insert the optic cartridge by carefully following the handling instructions SECU06 Temporary blocking Wait for the procedure that cools down the op...

Страница 26: ...oduct after the deadline specified beside this logo gel The batch number of the product is indicated beside this logo gel y RECYCLING AND TREATMENT Instructions for treatment of used products the WEEE...

Страница 27: ...network Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical public low voltage power supply network Vol...

Страница 28: ...ment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which is used exceed the applicable RF compliance level above sh...

Страница 29: ...l void the warranty E SWIN SAS will not be held responsible for any accident that may occur due to improper use or non compliance with the prescriptions of the present manual or the various informatio...

Страница 30: ...www e swin com 0197 ZA de la Pr v t Rue des C tes d Orval 78550 Houdan FRANCE 01 30 46 37 61 Ref M015GB000C12A rev C 2021 09 21 Copyright by E SWIN All rights reserved...

Отзывы: