FF05
65285
Version conflict:
Object data in the
flash are invalid
Reaction 1: Downramp actual
speed; remain in position
control state.
FF06
65286
No object for process
data; object cannot
be mapped
Reaction 1: Downramp actual
speed; remain in position
control state.
FF07
65287 Data not valid
Reaction 1: Downramp actual
speed; remain in position
control state.
FF08
65288 No convert function
Reaction 1: Downramp actual
speed; remain in position
control state.
Drive needs to be repaired.
FF09
65289 Process data overflow
Reaction 1: Downramp actual
speed; remain in position
control state.
Load IEC project again into device, configure device anew (if needs
be, create new project)
FF10
65296
Command syntax
error
Reaction 1: Downramp actual
speed; remain in position
control state.
Error history, retain variables and absolute positions invalid. Flash
defective? Verify shutdown sequence! New data block is created
and saved with the next shutdown.
FF11
65297 Value not valid
Reaction 1: Downramp actual
speed; remain in position
control state.
Load application data into device (configuration).
FF12
65298 Checksum error
Reaction 1: Downramp actual
speed; remain in position
control state.
Load application data into device (IEC61131-3 program). Turn
device off and back on again.
Update Firmware or adapt IEC program if necessary.
Please use a Compax3 tool release (C3Mgr) higher than R08-1 for
very old devices (firmware V01.xx.yy).
FF13
65299 Timeout error
Reaction 1: Downramp actual
speed; remain in position
control state.
FF14
65300 Overflow error
Reaction 1: Downramp actual
speed; remain in position
control state.
De-energize motor, then perform function
FF15
65301 Parity error
Reaction 1: Downramp actual
speed; remain in position
control state.
FF16
65302 Frame error
Reaction 1: Downramp actual
speed; remain in position
control state.
Find cause: Read objects 25.4 and 25.5
FF17
65303 Gateway Timeout
Reaction 1: Downramp actual
speed; remain in position
control state.
Load configuration into device or avoid WriteFlash command in
cam operation.
FF1A
65306
C3MCom: Wrong
Block-Check-
Character (BBC)
Reaction 1: Downramp actual
speed; remain in position
control state.
FF1B
65307 C3MCom: Timeout
Reaction 1: Downramp actual
speed; remain in position
control state.
Adapt buffer reservation for IEC program (Object 30.2) or download
IEC program again with the C3-Manager.
FF1C
65308 C3MCom: Overrun
Reaction 1: Downramp actual
speed; remain in position
control state.
Check IEC program for objects unknown to the current Firmware.
Maybe the wrong IEC Target was selected (e.g. C3F Target for C3).
FF1D
65309 C3MCom: Parity
Reaction 1: Downramp actual
speed; remain in position
control state.
Check IEC compiler settings and re-compile IEC program if
necessary. Update Firmware if necessary.
FF1E
65310 C3MCom: Frame
Reaction 1: Downramp actual
speed; remain in position
control state.
Configure device again (if needs be, create new project) and load
into device.