4-16
SkyView SE
Pilot’s User Guide
- Revision B
An ADAHRS labeled STANDBY is being used for cross-checking, but it is not being displayed on
the PFD.
PRIMARY / ALTERNATE ADAHRS Selection
The ADAHRS labeled PRIMARY is the one that will be preferentially chosen by SkyView SE as the
active ADAHRS.
An ADAHRS labeled ALTERNATE is one that is available to be used in the event of a failure or
problem with the primary ADAHRS. However, it normally won’t be
chosen for display on the
PFD unless the primary ADAHRS has failed or has manually been disabled.
To change which ADAHRS is the PRIMARY ADAHRS, highlight an ALTERNATE ADAHRS and press
the PRIMARY button to elevate it to PRIMARY status.
To disable an ADAHRS until SkyView SE is next powered up, simply highlight it with the joystick
and press the DISABLE button.
To see the same comparison screen that is presented when a cross-check error occurs, press
the COMPARE button at the bottom of the display.
Press BACK to exit the ADAHRS Source Selection Page or press EXIT to return to the Main Menu.
Either of these actions will save the ADAHRS source settings.
G Meter
Press G METER (Button 6) to toggle the G Meter on and off. When the G Meter is displayed, it
replaces the HSI/Compass Rose, though numerical magnetic heading above the HSI area
remains. The G Meter s
hows an analog “needle”
that indicates the instantaneous G loading of
the aircraft. Depending on how the G Meter is configured, the analog range may have yellow
and/or red caution ranges configured to visually indicate aircraft G limits are being approached.
Instantaneous G information is also shown digitally in the center of the gauge.
Figure 31
–