background image

Dynatron 900

+™

 

 

26 

D

YNATRON 

900+

™   

 

LIMITED WARRANTY

 

 

Dynatronics CORPORATION warrants the Dynatron 900+, to be free from factory defects in materials and workmanship 
under normal use for ONE YEAR from the date of purchase by the original owner.  If this product is defective within the 
warranty period, Dynatronics will, subject to the conditions set forth below: 

 

(1)  repair or replace defective parts at no charge within a reasonable period of time with new or remanufactured parts, at 
Dynatronics

’ option; and 

 

(2)  provide labor for the repair or replacement of defective parts under this warranty without charge. 

 

Parts  used  for  replacement  under  this  warranty  are  warranted  for  the  remainder  of  the  original  warranty  period.    THE 
REPAIR OR REPLACEMENT OF DEFECTIVE PARTS SHALL CONSTITUTE THE SOLE AND EXCLUSIVE REMEDY IN 
THE EVENT OF A BREACH OF WARRANTY. 

 

REGISTRATION  REQUIRED.    In  order  for  this  warranty  to  be  valid,  the  warranty  registration  card  (included  with  the 
product) must be filled out and returned to Dynatronics within 30 days of purchase by the original owner.  A copy of an 
invoice or receipt may be requested to verify purchase date. 

 

REPAIRS.  All repairs must be performed by an authorized service facility.  Any modifications or repairs by unauthorized 
parties will void this warranty. 

 

OBTAINING  WARRANTY  SERVICE.    Authorization  by  Dynatronics  is  required  before  obtaining  service  under  this 
warranty.  Therefore, before shipping or delivering this product to an authorized service facility for warranty service, call 
Dynatronics and obtain a return authorization number. 

 

PACKAGING AND SHIPPING.  Any device shipped to an authorized service facility for service under this warranty must 
be in the original shipping carton, freight prepaid, fully insured, and properly packed to prevent damage.   Dynatronics is 
not liable for any damage to the device while in transit.  Include a summary of the problem with the product.  Write the 
return authorization number obtained from Dynatronics on the shipping label. 

 

SHIPPING  COSTS.    Within  the  first  30  days  of  the  warranty  period,  Dynatronics  will  pay  all  necessary  shipping  costs 
associated  with  obtaining  service  under  this  warranty.    After  the  first  30  days  of  the  warranty  period,  the  owner  is 
responsible  for  all  costs  associated  with  shipping  the  product  to  an  authorized  service  facility.    Dynatronics  will  pay  all 
costs associated with shipping the product back to the owner after service is completed, and will ship the product using 
the same carrier or type of carrier and service that was used by the owner for the incoming shipment. 

 

EXCLUSIONS.  Any defect, malfunction or failure caused by or resulting from improper installation, service, maintenance 
or repair, or from abuse, neglect, transportation, accident, act of God, or other cause beyond the control of  Dynatronics 
will  not  be  covered  by  this  limited  warranty.    ANY  IMPLIED  WARRANTIES  COVERING THIS  PRODUCT,  INCLUDING 
BUT  NOT  LIMITED  TO  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  ARE 
LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER.   Dynatronics 
SHALL  NOT  IN  ANY  CASE  BE  LIABLE  FOR  SPECIAL,  INCIDENTAL,  CONSEQUENTIAL,  INDIRECT,  OR  OTHER 
SIMILAR  DAMAGES  ARISING  FROM  BREACH  OF  WARRANTY,  BREACH  OF  CONTRACT,  NEGLIGENCE,  OR  ANY 
OTHER  LEGAL  THEORY  EVEN  IF  Dynatronics  HAS  BEEN  ADVISED  OF  THE  POSSIBILITY  OF  SUCH  DAMAGES.  
SOME  STATES  DO  NOT  ALLOW  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY  LASTS  OR  THE 
EXCLUSION  OR  LIMITATION  OF  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  SO  THE  ABOVE  LIMITATION  OR 
EXCLUSION MAY NOT APPLY TO YOU.  THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU  MAY 
ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 

 

For more information concerning repairs, operation, or technical assistance, please contact the Dynatronics dealer 
nearest you, or contact Dynatronics directly at: the address below. 

 
 
 

 
 
 
 
 
Dynatronics Corporation

 

7030 Park Centre Drive  •  Salt Lake City, Utah  84121  •  (801)  568-7000  (800)  874-6251 

Содержание 900+

Страница 1: ......

Страница 2: ...imes DANGER Explosion Hazard Do not use in the presence of flammable gas or anesthetics Do not use the Traction System near X ray or Diathermy devices These devices may emit high frequency noise that could affect the operation of the Dynatron 900 Traction device INDICATIONS FOR USE Dynatron 900 Traction System The Dynatron 900 Traction system is intended for medical purposes for use in conjunction...

Страница 3: ... SPINAL DECOMPRESSION 13 CONTRAINDICATIONS 13 PRECAUTIONS WARNINGS 13 SECTION V TECHNICAL INFORMATION 14 SUGGESTED MAINTENANCE SCHEDULE 14 SERVICE TO BE PERFORMED BY A TECHNICIAN 14 MAINTENANCE PERFORMED BY USER 14 CAUTION 14 WARNING 14 RETURNING A UNIT FOR REPAIR 15 PACKAGING AND SHIPPING 15 CARE AND CLEANING INSTRUCTIONS 15 ENVIRONMENTAL CONDITIONS 15 SECTION VI ASSEMBLY AND MAINTENANCE 16 DYNAT...

Страница 4: ...Dynatron 900 iv ...

Страница 5: ...ructions for the Dynatron 900 Microprocessor controlled Traction system A copy of this manual should be left with the device at all times BEFORE YOU TREAT A PATIENT Before administering a treatment to a patient with the Dynatron 900 familiarize yourself with all the operating instructions as well as the contraindications warnings and precautions for this device After reading the information provid...

Страница 6: ...re covered by the warranty policy Warranty registration must include the device serial numbers Read the operating instructions in this manual carefully before proceeding with a treatment Connect the AC power cord which is equipped with a hospital grade UL listed plug to a properly grounded 110 120V 60 Hz AC 220V 60 Hz if applicable outlet The power cord must be firmly plugged into the Dynatron 900...

Страница 7: ...0N 200 lbs approximately 91kg 890N Note 5 lbs 2 5kg 25N for all settings Traction Force Compensation Computerized Automatic Compensation Force Units Pounds Kilograms or Newtons Hold Rest Time 1 99 sec independently set Treatment Time 1 99 min 2 Traction Speed 9 35 sec 0 200 lbs variable speed motor stepless continuous and adjustable Continuous Traction Release Time 00 99 seconds by static traction...

Страница 8: ... at any time The Remote Stop should be plugged into the device prior to turning on the device 7 SP KEY Located toward the left side of the control panel the SP Key toggles through four settings that control the volume of the audible signals Mute Low Mid Max 8 N KG LB KEY This key is located toward the right side of the control panel It allows the user to control the unit of measurement in which th...

Страница 9: ...Dynatron 900 5 DYNATRON 900 NUMBERED FEATURES ...

Страница 10: ... above the Rest Force knob Rest Time is selected by pressing the arrow selector keys under the Rest Display Window This display indicates the amount of time the rope tension will Rest following the release phase of the traction cycle Rest force time ranges from 1 99 seconds and may be adjusted in 1 second intervals When a static traction treatment is desired press the down the Rest Force Arrow Key...

Страница 11: ...the device in a place where the cord could be tripped over or accidentally pulled out of its socket during a treatment 21 TRACTION PULLEY The Traction Pulley can be rotated to any desired position 22 TRACTION CORD The traction rope is connected to the spring loaded clip by a knot 23 SPRING LOADED TRACTION CLIP The traction Clip is used to attach the traction belts to the traction device When opera...

Страница 12: ...d carefully position the patient CERVICAL THORACIC AND PELVIC HARNESSES The cervical thoracic and pelvic harnesses must be properly fitted according to manufacturers instructions Belts should be securely tightened without creating discomfort Harnesses secure the patient to the traction device while supporting the musculature thus allowing for the proper application of the distraction forces POSITI...

Страница 13: ...me is selected by pressing the up down arrow keys below the Rest Display This timer determines the amount of time the Rest tension will hold after reaching the preset Rest Force Rest Force Time ranges from 0 99 seconds and may be adjusted in 1 second intervals When a static traction treatment is desired set the Hold Time at The Rest Force setting is ignored 6 Set Hold Force 4 200 lbs 2 91 kg or 20...

Страница 14: ...LED above the Rest key will flash the Treatment Time Display Window will flash 00 and the tension on the rope will ramp down to 4 lbs Press the Reset Key to conclude the treatment and release all tension from the rope The 900 is now ready for program changes or to setup a new treatment ...

Страница 15: ... hand it to the patient 3 Turn on the Dynatron 900 device 4 Set Treatment Time 1 99 min 5 Set Hold Force Timer 1 99 sec 6 Set Rest Force Timer 1 99 sec 7 Set Hold Force 4 200 lbs or 2 91 kg 8 Set Rest Force 0 197 lbs or 0 90 kg Must be set lower than Hold Force value 9 Adjust Speed Fast Intermittent Cycle Slower Intermittent Cycle with Longer Ramp Time 10 Press START HARMONIC INSTRUCTIONS 1 Prepar...

Страница 16: ... be set lower than Hold Force value 14 Adjust Speed Slow minimum setting 15 Press START NOTE AS A SAFETY PRECAUTION IT IS NECESSARY TO RESET BOTH THE HOLD AND REST FORCES WHENEVER THE POWER SWITCH IS ARE TURNED ON FAILURE TO DO SO WILL RENDER THE DEVICE INOPERABLE SPECIAL USAGE PROCEDURES ADJUST HOLD REST FORCES AFTER ATREATMENT IS IN PROGRESS 1 Once the initial Hold Force is reached during a trea...

Страница 17: ...joint and or soft tissue injury Any condition that grows worse after treatment The presence of vascular compromise PRECAUTIONS WARNINGS Ligamentous Strains and Joint Hypermobility Patient s with Traction Anxiety causing muscles to become over tense and or cardiac respiratory insufficiencies Discontinue treatment immediately if there is an increase in symptoms or pain or if paresthesia prickling or...

Страница 18: ... to the unit and may endanger the life of the patient The unit may only be opened and serviced by authorized personnel Unplug the unit before opening Dynatronics recommends that the Dynatron 900 be calibrated annually to ensure the unit is working at peak performance When disposing of a Dynatron 900 unit comply with the laws and procedures required in your area according to directives in ISO 14000...

Страница 19: ...or device CARE AND CLEANING INSTRUCTIONS Clean the outer surface of the Dynatron 900 device with a slightly damp or lightly moistened cloth Mild household cleaners work well on the frame Do not spray the solution directly on the unit First moisten the cloth and then wipe the unit off Solvents caustic solutions or harsh or abrasive cleaners must never be used Avoid stretching electrical cords to fu...

Страница 20: ...ced or removed from the device turn the pulley head to the left until the breach points are aligned and the pulley easily slips from the enclosure Do not force REMOVING THE CHASSIS 1 Remove the two screws from the back panel of the chassis A 2 Remove the bottom plate and side panels will fall free ...

Страница 21: ...e device with hand screws E DYNATRON 900 PLATFORM INSTALLATION 1 Align hole A on the machine with pin F on the installation plate 2 Turn the machine to the desired orientation 3 Tighten the 4 hand screws E DYNATRON 900 TABLE INSTALLATION 1 Tighten stud to two screw holes G 2 Attach universal mounting bracket to stud 3 Tighten the knobs Orientation Options ...

Страница 22: ...HINED HOLE SIZES A Alignment hole 3 8 dia B Alignment set pin holes dia C Screw holes for table mount wall mount 5 16 18UNC D Knob for wall bracket 5 16 18UNC E Screw holes for stand mount or mounting bracket 5 16 18UNC Device Front ...

Страница 23: ...ble through the hole of pulley B go around the main shaft and under cable pull cable tight to secure the end of cable against the main shaft Fig 1 4 Pass side P2 of cable to pulley C Fig 2 5 Then pass pulley D Fig 3 6 Go around head pulley Fig 4 7 Tie the hook with cable as shown in Fig 5 7 8 En circle the cable on pulley B 9 Turn pulley B until the keyway faces you Fig 8 10 Turning the rotary spr...

Страница 24: ...sert the new fuse STEP 4 Insert the fuse case into the fuse holder STEP 5 Turning clockwise use a screwdriver to reattach the fuse cover FUSE 250V 0 8A 220 240V STEP 1 Turning counter clockwise use a screwdriver to remove the fuse case cover STEP 2 Remove the fuse and fuse case Remove the used fuse from the fuse case Insert the new fuse STEP 3 Insert the fuse case into the fuse holder Turning cloc...

Страница 25: ...of the following symbols are included in the labeling for this device Definitions accompany each symbol Please read the Operations Manual Carefully before using this device Electrical Safety Class 1 Type BF Manufacturer s ID Label 120V Manufacturer s ID Label 220V ...

Страница 26: ...ely to cause any interference in nearby electronic equipment RF emissions CISPR 11 EN55011 Class A The Dynatron 900 and accessories is suitable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions...

Страница 27: ...al or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode Compliant Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 Ut 95 dip in Ut for 0 5 cycle 40 Ut 60 dip in Ut for 5 cycles 70 Ut 30 dip in Ut for 25 cycles 5 Ut 95 dip in Ut for 5 ...

Страница 28: ...ot apply to all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environm...

Страница 29: ...rference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the Dynatron 900 and accessories as recommended below according to the maximum power of the communications equipment Separation distance meters according to frequency of transmitter Rated maximum output power of transmitter W 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 0...

Страница 30: ... of the problem with the product Write the return authorization number obtained from Dynatronics on the shipping label SHIPPING COSTS Within the first 30 days of the warranty period Dynatronics will pay all necessary shipping costs associated with obtaining service under this warranty After the first 30 days of the warranty period the owner is responsible for all costs associated with shipping the...

Страница 31: ...Dynatron 900 27 ...

Страница 32: ...n contained in the operator s manual for this device o I have received in service training from my dealer and or Dynatronics for this device IMPORTANT If there is anything about the operation or use of your Dynatron device that you do not understand contact your dealer or Dynatronics for instruction As a trained medical practitioner you are solely responsible for determining appropriate applicatio...