Machine description
4812158801_E.pdf
2018-04-03
3
4
If delayed regeneration has been ongoing for so long
that the DPF lamp (3) flashes and the engine control
lamp (4) has come on, the filter must be regenerated
manually before the filter becomes full.
Reduced motor power occurs automatically.
Manual regeneration is started by turning the DPF
knob to the right; the knob springs back immediately to
the automatic (middle) position.
5
If manual regeneration is not performed after a
warning to do so, the engine heating lamp (5) comes
on at the same time as DPF lamp continues to flash.
Continuing to work with the machine without activating
regeneration will result in the need to service or
replace the DPF filter, and the engine may also be
damaged.
6
The lamp for high exhaust temperature (the HEST
lamp) (6) comes on when the temperature of the
exhaust fumes is high in conjunction with filter
regeneration.
The lamp can also come on during normal engine use
or during manual regeneration.