Dynamic Fluid Measurement
SFC3 Liquid Pulse Manual
Modbus Data
– 4-9
MODBUS ADDRESS TABLE
– 16 BITS
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
30020
Flow Computer ID
0 Inferred
Read/Write
30021
reserved
30022
Port 1 Modbus Type (0=RTU,1=ASCII)
0 Inferred
Read/Write
30023
Port 1 Parity(0=None,1=Odd,2=Even)
0 Inferred
Read/Write
30024
Port 1 Baud Rate(0=1200,1=2400,3=4800,4=9600)
30025
reserved
30026
Port 1 RTS Delay in Milliseconds
0 Inferred
Read/Write
30027-30030 reserved
30031
Port 2 Select 0=RTS,1=Printer
0 Inferred
Read/Write
30032
Port 2 Modbus Type (0=RTU,1=ASCII)
0 Inferred
Read/Write
30033
Port 2 Parity(0=None,1=Odd,2=Even)
0 Inferred
Read/Write
30034
Port 2 Baud Rate(0=1200,1=2250,3=4800,4=9600)
30035
Printer Baudrate(0=1200,1=2400,3=4800..)
0 Inferred
Read/Write
30036
Port 2 RTS Delay in Milliseconds
0 Inferred
Read/Write
30037
Printer Number of Nulls
0 Inferred
Read/Write
30038-30085 Spare
30086
Analog #1 Input Scale Data
0 Inferred
Read
30087
Analog #2 Input Scale Data
0 Inferred
Read
30088
Analog #3 Input Scale Data
0 Inferred
Read
30089
Analog #4 Input Scale Data
0 Inferred
Read
30090
Analog #5 Input Scale Data
0 Inferred
Read
30091
Analog #6 Input Scale Data
0 Inferred
Read
30092
Analog #7 Input Scale Data
0 Inferred
Read
30093
Analog #8 Input Scale Data
0 Inferred
Read
30094
RTD #9 Input Scale Data
0 Inferred
Read
30095
RTD #10 Input Scale Data
0 Inferred
Read
30096
RTD #11 Input Scale Data
0 Inferred
Read
30097
RTD #12 Input Scale Data
0 Inferred
Read
30098
Density Input #1 Scale Data
0 Inferred
Read
30099
Density Input #2 Scale Data
0 Inferred
Read
30100
Spare
30101
Switch Output #1 Assign
0 Inferred
Read/Write
30102
Switch Output #2 Assign
0 Inferred
Read/Write
30103
Switch Output #3 Assign
0 Inferred
Read/Write
30104
Switch Output #4 Assign
0 Inferred
Read/Write
30105
Switch Output #5 Assign
0 Inferred
Read/Write
30106
Switch Output #6 Assign
0 Inferred
Read/Write
30107
Switch Output #7 Assign
0 Inferred
Read/Write
30108
Switch Output #8 Assign
0 Inferred
Read/Write
30109
Switch Output #9 Assign
0 Inferred
Read/Write
30110
Switch Output #10 Assign
0 Inferred
Read/Write
30111
Switch Output #11 Assign
0 Inferred
Read/Write
30112
Switch Output #12 Assign
0 Inferred
Read/Write
30113
Switch Output #13 Assign
0 Inferred
Read/Write
30114
Switch Output #14 Assign
0 Inferred
Read/Write
30115
Switch Output #15 Assign
0 Inferred
Read/Write
30116
Switch Output #16 Assign
0 Inferred
Read/Write
30117
Switch Output #17 Assign
0 Inferred
Read/Write
Содержание SFC3
Страница 15: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Страница 17: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 12 Date 8 1 2019 ...
Страница 18: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 13 Date 8 1 2019 ...
Страница 22: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 17 Date 8 1 2019 Wiring the Analog Inputs 1 4 ...
Страница 26: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Страница 35: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 30 Date 8 1 2019 ...
Страница 37: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 32 Date 8 1 2019 Wiring of Brooks Prover ...
Страница 38: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 33 Date 8 1 2019 Wiring of Calibron Prover ...
Страница 88: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Flow Equations 3 5 Date 8 1 2019 ...