Dynamic Fluid Measurement
SFC3 Liquid Pulse Manual
Quick Start
— 1-28
Date: 8/1/2019
Wiring of Switch/Pulse Outputs:
Scroll to
Switch output
under
Wiring
and press <
ENTER>
. The wiring diagram shows switch 1
and 2 and the return. Please note that switches 3, 4, and 5 cannot be used for pulse output; switches 1 and 2
can be used for pulse or switch output. See also
I/O Expansion
. Notice that the switch outputs are
transistor type outputs (open collector type with maximum DC rating of 350 mA continuous at 24 VDC)
and require external power.