Dynamic Fluid Measurement
SFC3 Liquid Pulse Manual
Data Entry 2-12
Date: 8/1/2019
A r e a T h e r m a l C o e f f i c i e n t E - 7 ( P i s t o n P ro v e r )
This is the coefficient of expansion for prover wall
mild carbon
62.0
10
-7
/
F
304 stainless
96.0
10
-7
/
F
316 stainless
88.3
10
-7
/
F
7–14 pH stainless
60.0
10
-7
/
F
P
R O V E R
B
A S E
T
E M P E R A T U R E
The temperature in which the prover volume was established. All steel correction factors will be based on
base temperature.
P
R O V E R
B
A S E
P
R E S S U R E
The prover pressure correction factors will be based on the reference calibration pressure. The modulus of
elasticity combined with the live pressure are used to calculate wall expansion due to pressure.
P re - t r a v e l i n V o l u m e
After the second detector switch is tripped. The Flow Computer allows for certain delay period
proportional to time between prover run first and second detector switch. To allow for the prove ball to
stabilize, after the time expires, the launch sequence will be re-initiated.
P ro v e A b o rt T i m e O u t i n Se c o n d s
If the prove run was not achieved in the set time, then the prove will be aborted. The reason for this
function is to accommodate the possibility the second detector switch was not triggered for one reason or
another, or the proving was launched from the wrong direction.
U
P S T R E A M
/ D
O W N S T R E A M
P
R O V E R
V
O L U M E
The prover volume in barrels at reference conditions per water draw.
P
R O V E R
D
I A M E T E R
The diameter of the prover in inches.
P
R O V E R
W
A L L
T
H I C K N E S S
The thickness of prover wall in inches assuming single wall prover.
Mo d u l u s o f E l a s t i c i t y
The elasticity coefficient of prover wall material.
C o e f f i c i e n t o f C u b i c a l E x p a n s i o n E - 7
mild carbon
62.0
10
-7
/
F
304 stainless
96.0
10
-7
/
F
316 stainless
88.3
10
-7
/
F
7–14 pH stainless
60.0
10
-7
/
F
P
R O V E R
T
E M P E R A T U R E
S
A M P L E
P
E R I O D
The prover temperature should be stable before proving. This would indicate that the prover and the fluid
through the prover have similar temperatures. The sample period configured is a command to the Flow
Computer to sample the prover temperature every so many minutes and compares the temperature to the
previous sample.
Содержание SFC3
Страница 15: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Страница 17: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 12 Date 8 1 2019 ...
Страница 18: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 13 Date 8 1 2019 ...
Страница 22: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 17 Date 8 1 2019 Wiring the Analog Inputs 1 4 ...
Страница 26: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Страница 35: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 30 Date 8 1 2019 ...
Страница 37: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 32 Date 8 1 2019 Wiring of Brooks Prover ...
Страница 38: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 33 Date 8 1 2019 Wiring of Calibron Prover ...
Страница 88: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Flow Equations 3 5 Date 8 1 2019 ...