Dynamic Fluid Measurement
SFC3 Liquid Pulse Manual
Data Entry 2-21
Date: 8/1/2019
M
E T E R
F
A C T O R
O
V E R R I D E
Enter Meter Factor to override the current batch meter factor. This meter factor is used only for the current
batch. If permanent modifications to the meter factor are needed, change the meter factor in the meter
factor file.
G
R A V I T Y
O
V E R R I D E
Enter Gravity Override to replace current gravity. The gravity override is a non-retroactive gravity and will
not override the product file gravity. It only applies to the current running batch.
B S & W
O
V E R R I D E
Enter the BS&W override for the current batch (none retroactive).
A
L P H A
T
E- 6
O
V E R R I D E
Enter Alpha T Override to the batch. It will not effect the Alpha T value in the product file. Alpha T is the
thermal expansion coefficient for the selected product. The flow computer divides by 1000000.
Example: 0.000355 = 355 / 1000000
E
Q U I L I B R I U M
P
R E S S U R E
O
V E R R I D E
Enter the equilibrium pressure override for the current batch.
M
E T E R
T
E M P E R A T U R E
O
V E R R I D E
This value is entered when no live temperature is available, or different value from live value should be
used.
M
E T E R
P
R E S S U R E
O
V E R R I D E
Pressure override can be used when no live pressure transmitter is connected to the Flow Computer.
C T L
S
L O P E A N D
I
N T E R C E P T
Slope and intercept are used if Ethanol product is configured.
Security Code
Several levels of security codes have been selected to fit different levels of responsibility. Up to six
alphanumeric codes can be used for each entry. If the security code is not used, then there will not be any
security code prompt in the menu.
Содержание SFC3
Страница 15: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Страница 17: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 12 Date 8 1 2019 ...
Страница 18: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 13 Date 8 1 2019 ...
Страница 22: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 17 Date 8 1 2019 Wiring the Analog Inputs 1 4 ...
Страница 26: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Страница 35: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 30 Date 8 1 2019 ...
Страница 37: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 32 Date 8 1 2019 Wiring of Brooks Prover ...
Страница 38: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Quick Start 1 33 Date 8 1 2019 Wiring of Calibron Prover ...
Страница 88: ...Dynamic Fluid Measurement SFC3 Liquid Pulse Manual Flow Equations 3 5 Date 8 1 2019 ...