Hardware and Software Design • Manufacturing Services
page 33
FE Z Stop Registers
0014
FE01
Z0_STOP
0018
FE01
Z1_STOP
0054
FE23
Z2_STOP
0058
FE23
Z3_STOP
0114
FE45
Z4_STOP
0118
FE45
Z5_STOP
0154
FE67
Z6_STOP
0158
FE67
Z7_STOP
Zx Stop : Read – Write
20 – 0 set the number of loops of X and Y to implement. If Y is not set then use a larger X value and program to
0.
Please note that all three stop values count from 0 to the value programmed – $F is 0 through F for a total of
16…program in “N-1” to get the count that you desire.
FE X Total Counter Read-back
001C
FE01
X_TOTAL_0_RDBK
0020
FE01
X_TOTAL_1_RDBK
005C
FE23
X_TOTAL_2_RDBK
0060
FE23
X_TOTAL_3_RDBK
011C
FE45
X_TOTAL_4_RDBK
0120
FE45
X_TOTAL_5_RDBK
015C
FE67
X_TOTAL_6_RDBK
0160
FE67
X_TOTAL_7_RDBK
X Total x Counter : Read only
Read the total number of stored samples count value. The count value is double clocked and held to be stable with
the PCI based clock. Counter occupies data bits 26 – 0. Please note that the counter resets to 0 at the beginning