Dynamax Inc
46
5.3 Monitor Data In Real Time
With communication established between software and the data logger, select
Monitor Values
tab in PC400 window. This is similar to Numeric panel in PC208 and LoggerNet.
1. Click on Add button to open the signal list. Select Public from the left column to display public
variables available in the right column. Select desired signals from the right column. Click on a
cell in the Monitor values window, Click Paste button. All the selected signals will be displayed in
the Monitor values window. Note that if you have a long averaging interval, it will take that amount
of time to see a new reading. You may want to temporarily select a smaller interval or use
maintenance program to test the operation. And then download the program with required long
term averaging interval later. Any unwanted signals in Monitor window can be removed simply by
selecting the cell and click
Delete
button.
2. Once in the Add menu, to select a range of values select the starting label, click on the beginning
(for example TCAir_C) and then a
SHIFT-Click
on the ending of the range (for example RG_mm)
and then click the
Paste
button.
3.
Note any variables displaying a “-NAN” are a out of range, or in the case of a sensor input
location, it is a open circuit wire.
4. In the figure below all Dynamet 5 sensor variables are displayed in the monitor mode.
Содержание Dynamet 5
Страница 1: ...DYNAMET 5 Weather Station User Manual v 1 1 ...
Страница 3: ...Dynamax Inc 2 ...
Страница 5: ...Dynamax Inc 4 ...
Страница 18: ...Dynamet 5 17 ...
Страница 19: ...Dynamax Inc 18 Dynamet 5 Logger Assembly wiring internal battery and solar charge regulator ...
Страница 66: ...Dynamet 5 65 Enter data number corresponding to the remote modem Phone modem GSM cellular modem ...
Страница 72: ...Dynamet 5 71 Logger 4 Logger 3 Logger 2 Logger 1 ...
Страница 74: ...Dynamet 5 73 ...
Страница 75: ...Dynamax Inc 74 ...
Страница 79: ...Dynamax Inc 78 Appendix C SENSOR SPECIFICATIONS ...