Dynamet 5
23
3.2.3
Install Dynamet 5 Enclosure
Dynamet 5 weather station enclosure contains CR1000 data logger, and other storage of
communication peripherals if any. Sensor cables, Power cables, Communication cables
connected to the data logger or any peripherals routed out of the enclosure through a PVC
conduit. So it is not necessary of an end-user to make any wiring inside the enclosure. All
the connectors are accessible out of the box. Position the enclosure on the north side of the
mast or tower (northern hemisphere). Secure enclosure as shown in the figure using U-bolts
and mounting brackets. Route the 12AWG wire from the Ground Lug on the enclosure to the
tripod-grounding clamp. Tighten the screws. Grounding is critical not only for the accuracy of
data/ reduce signal noise but also to protect equipment from any lightening surges.