Power down the chassis. Make sure that the card is properly seated in the CompactPCI
chassis. Because of the five-row backplane, a considerable amount of insertion force is
required.
S
TATUS
LED S
TAYS
R
ED
If the Status LED stays red after power-up, then PBIT found one or more problems or PBIT
was not run. The DRT command displays addresses for the binary, ASCII, and start-up PBIT
binary and ASCII DRTs. It also displays the ASCII DRTs for both PBIT and start-up PBIT. Use
the GPM drt command to display the DRT as shown in the example below:
F
IGURE
4.6: Sample Diagnostics Results Table (DRT)
SCP/DCP-122, PowerPC 750FX General Purpose Monitor, Version 8.0
Copyright 1998 to 2003 DY 4 Systems
Type ? for help
40000000* drt
DRT header address: 0x5400
Binary DRT address: 0x5440
Diag Sub Result Progress Fail a Fail b Fail c Fail d
Pass 0 Pass 0 0 0 0 0
CpuSpaceDecode 0 Pass 0 0 0 0 0
EEPROM 0 Pass 0 0 0 0 0
RAM 0 Pass 0 0 0 0 0
Serial Port 0 Pass 0 0 0 0 0
Serial Port 0 Pass 0 0 0 0 0
Base Card Diag 0 Pass 0 0 0 0 0
RAM 0 Pass 0 0 0 0 0
Partition 0 Pass 0 0 0 0 0
ISP1160 0 Pass 0 0 0 0 0
FPGA TIMER 0 Pass 0 0 0 0 0
L2 Cache 0 Pass 0 0 0 0 0
PCI Ven/Dev ID 0 Pass 0 0 0 0 0
GT64260Ethernet 0 Pass 0 0 0 0 0
BCM5221 0 Pass 0 0 0 0 0
ECC 0 Pass 0 0 0 0 0
MAX6634 0 Pass 0 0 0 0 0
ASCII DRT address: 0x5A00
CLD complete: 17 diagnostics were executed