SCP/DCP-122 G
ETTING
S
TARTED
M
ANUAL
D
Y
4 S
YSTEMS
I
NC
.
4-16
812628 V
ERSION
1 O
CTOBER
2003
I
NITIATING
THE
P
OWER
-U
P
S
EQUENCE
P
OWER
-U
P
Switch the CompactPCI chassis on.
I
NITIAL
LED A
CTIVITY
Immediately on power-up, the Status LED will indicate red.
Once the card passes its initial diagnostics, PBIT turns the Status LED green. If a diagnostic
fails, the LED remains red.
D
ISPLAYING
THE
I
NITIAL
S
CREEN
M
ESSAGE
After control is transferred to the GPM, pressing any key on the keyboard will inform the GPM
that I/O data is being received from the serial data port. The GPM will then display a sign-
on message similar to the following:
SCP/DCP-122, PowerPC 750FX General Purpose Monitor, Version 8.0
(c) DY 4 Systems Inc.
Type ? for help
40000000*
The last line is the initial prompt which shows the PCI base address of the card. In this
example the base address is 4000 0000H.
Cross Reference
If the Status LED stays red after the power-up, then PBIT has found one or more problems
or the selected execution sequence did not include PBIT. See “Troubleshooting” on page
4-17 for information on locating the problem.
Cross Reference
Type '?' at the prompt to display the help screen for the GPM. For more detailed information
on using the GPM, refer to the V8 Foundation Firmware User’s Manual (808006).