13. TECHNICAL DATA
Softener type
Nominal flow
Max. flow (2 -6 bar)
Pressure at
nominal flow rate
Operating pressure
Min – Max (bar)
Resin volume
Capacity based on
dwelling and number
of people
Dimensions (H-L-P)
Salt tank capacity
Operating weight
ø inlet hose
ø outlet hose
ø regeneration pipes
ø safety pipes
Power rating
Maximum power
rating (during
regeneration)
Salt consumption
Brining efficiency
according to standard
EN 14743
Water consumption
for regeneration
Vi50 Monobloc
1,5 m³/H
1,3 à 2,6 m³/H
Min 2 bar
2-6
10L
+/- 180 m³/yr for
an inlet hardness
of +/- 35°f
130-20-30 cm
25 kg
53 kg
4/4”-3/4”
4/4”-3/4”
8 x 14 mm
10 x 14 mm
4,4 W
10,36 W
+/- 0,8 kg / m³
of softened water
Minimum 4 mol
(400 g of CaCO3)
+/- 34 L / m³
of softened water
Vi50 Duo
1,5 m³/H
1,3 à 2,6 m³/H
Min 2 bar
2-6
10L
+/- 180 m³/yr for
an inlet hardness
of +/- 35°f
75-40-30 cm
40 kg
68 kg
4/4”-3/4”
4/4”-3/4”
8 x 14 mm
10 x 14 mm
4,4 W
10,36 W
+/- 0,8 kg / m³
of softened water
Minimum 4 mol
(400 g of CaCO3)
+/- 34 L / m³
of softened water
Vi30 Duo
1,5 m³/H
1,6 – 2,8 m³/H
Min 2 bar
2-6
6L
max. 90 m³/yr for
an inlet hardness
of +/- 35°f
61-40 -30 cm
25 kg
45 kg
4/4”-3/4”
4/4”-3/4”
8 x 14 mm
10 x 14 mm
4,4 W
10,36 W
+/- 0,8 kg / m³
of softened water
Minimum 4 mol
(400 g of CaCO3)
+/- 34 L / m³
of softened water
Vi100 Duo
1,5 m³/H
1,2 - 2,4 m³/H
Min 2 bar
2-6
20L
+/- 180 m³ at 250
m³/yr for an inlet
hardness of +/- 35°f
or consumption
of +/- 180 m³ for a
hardness of > 40°f
up of a max 50°f
beyond switching to
suitable model.
130 -40 -30 cm
40 kg
85 kg
4/4”-3/4”
4/4”-3/4”
8 x 14 mm
10 x 14 mm
4,4 W
10,36 W
+/- 0,8 kg / m³
of softened water
Minimum 4 mol
(400 g of CaCO3)
+/- 34 L / m³
of softened water