ENGLISH
46
Parameter
Value of the
parameter
Settings available to the customer (left side of the screen), press on then to access :
H0 : corresponds to hours (0 à 23)
H1 : corresponds to minutess (0 à 59)
H2 : corresponds to the interval between 2 regenerations (24 – 48 – 72 – 96 H)
H3 : corresponds to the time of regeneration (0 à 23)
P4 : 00 (corresponds to nothing).
10.2. Setting the time :
a) Push and immediately , your display shows H0/figure (Eg : = 6 hours)
Push to change to the desired hour.
Confirm by pushing on ; your screen shows H1/figure.
(Eg : = 14 minutes)
Push to change to the desired minutes.
Exit program by pushing .
b) Setting the regeneration hour : go up to the H3 setting.
Push then 4 times ; your display shows H3/figure
(Eg : = 2 hours = regeneration at 2 a.m).
Push to change to the time you want your unit to regenerate.
Exit program by pushing .
c) Displaying total volume remaining before regeneration : Press .
The volume of water will be displayed for 5 seconds before automatically returning to the time display.
The display of the volume of water is distinguished by a flashing light on the lower right of the screen.
10.3. Special features of the softener
10.3.1. Initiate an immediate regeneration
Press directly on . The different phases of regeneration will scroll . . 01, . . 03, etc.
10.3.2. Holiday mode (when leaving for more than a week)
Before leaving on holiday : Push and confirm directly on . The phase beginnings (. . 01 and . . 03) for
regeneration will scroll on the screen (length: +/- 15 minutes) When the unit shows . . 04, unplug from electrical
power outlet.
Upon returning from holiday : plug into the electrical power outlet > the keyboard shows . . 04. Press
The unit runs a unit rinse and automatically returns to operating position.
10.4. Alarms (nACl + CALL)
10.4.1. nACL Alarm : salt
The nACL alarm is a safety feature to draw the softener owner’s attention to the salt level.
The salt level in the tank is not zero when the alarm comes on. There is still about 10 to 15 cm of salt (a
safety level).
When the screen shows a flashing nACl, it is necessary to reload the salt tablets in the salt tank as above.
After having reloaded the salt tank, push . A regeneration process will initiate and will automatically return the alarm
settings to zero.
Do not reload salt between two alarm displays..
10.4.2. CALL Alarm : maintenance
The CALL alarm is the maintenance alarm for the softener. This is activated when the unit is put into operation
with a maintenance contract or during the first contract maintenance.
P
ll
ll
P
P
P
P
P
ll
ll
ll
ll
P
ll