![Duerkopp Adler 745-34 Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350099.webp)
12.5 Lifting motion and suspension of the folder
Caution: Danger of injury !
Switch off the main switch.
Check and adjust lifting motion and suspension of the folder only with
the main switch turned off.
Standard checking
The folder 1 is suspended flexibly and is lifted by the pneumatic
cylinder 2.
In non-lifted position the folder must be lifted by the elastic force only.
–
Swing the folding station out a little.
–
Press the folder 1 down by hand.
It must be possible to press it down to the sliding sheets.
–
Release the folder.
The folder must be lifted by the spring.
Correction
–
Swing the folding station out.
–
Loosen screw 3 and adjust it in the slotted hole in such a way that
the folder is safely lifted.
–
Tighten screw 3.
–
Swing the folding station back and let it snap in.
Stop for the folder height
The center knife point in its lowest position must not project from the
folder sole. Otherwise the fabric is damaged.
–
Adjust the stop 4 correspondingly.
97
4
2
1
3
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...
Страница 147: ...145 1 2 3 2 3 4 5 9 10 4 5 6 7 1 8 ...