![Duerkopp Adler 745-34 Скачать руководство пользователя страница 119](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350119.webp)
13.5.4
Adjusting the flap clamps as to the rest table
40 + 3 mm
Standard checking
Not only the swivelling width of the flap clamps but also the position of
the rest table can be adjusted. The swivelling width can individually be
set according to the operator; then the rest table has to be adjusted so
that the stationary flap clamp is flush and parallel to the rest table with
a distance of
8 to 12 mm
. (See sketch page 112)
Correction of the swivelling width
–
Loosen nut 3.
–
Set the swivelling width by turning the bush 4.
–
Tighten nut 3.
Correction of the rest table
–
Loosen screw 5.
–
Turn rod 6 until the rest table is flush with the stationary flap clamp.
–
Tighten screw 5.
–
Loosen screws 7.
–
Adjust the rest table parallel to the flap clamp with a distance of
8-12 mm.
–
Tighten screws 7 again.
117
4
3
5
6
7
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...
Страница 147: ...145 1 2 3 2 3 4 5 9 10 4 5 6 7 1 8 ...