10
±3 µµ
Adjusting the flap transfer position
Precondition:
The flap clamp lifting device is adjusted as described in chapter 13.5.3.
Standard checking
The stationary flap clamp 1 of the flap turning device must stand
20
3 mm
underneath the rest table 3. The lateral distance of flap
clamp 1 of the flap turning device and of flap clamp 2 of the feeding
device should amount to
10
3 mm
.
The
stationary
flap clamps of the turning and feeding device have to
be flush.
Correction of the distance to the rest table
–
Loosen the counternut 5.
–
Turn the screw 4 so that the stationary flap clamp 1 stands
20 ± 3
mm
underneath the table 2.
–
Tighten the counternut 5.
Correction of the lateral distance of the flap clamps
–
Loosen the counternut 7 and set the distance with the adjusting
screw 6.
–
Tighten the counternut 7.
Correction of transfer (flap clamps flush)
–
Loosen nut 11.
–
Turn the bush 12 until the flap transfer from flap clamp F to flap
clamp B is carried out without delay. (i.e. adjust flap clamps 1 and 2
so that they are flush)
–
Tighten nut 11.
122
5
4 9 10
3
2
1
6
7
20
±
3
m
m
10 ±
3 mm
11
12
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...
Страница 147: ...145 1 2 3 2 3 4 5 9 10 4 5 6 7 1 8 ...