![Duerkopp Adler 745-34 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350028.webp)
2.4.10
Exchanging the needle holder
Caution: Danger of injury !
Switch off the main switch.
Check and exchange the needle holder only with the sewing unit
switched off.
ATTENTION !
For changing a needle holder the needle bar in question must be in
position “down”.
The other needle bar has to be disconnected.
–
Loosen the screw 3.
–
Remove the needle from needle holder 2.
–
Press down latch 1 for connection of the needle bar and hold it
pressed.
–
Switch off the needle bar by turning the handwheel.
–
Keep on turning the handwheel.
The actuated needle bar switches off.
–
Keep on turning the handwheel until the needle bar is in position
“down”.
–
Loosen the screw 4.
–
Unscrew the needle holder 2 from the needle bar.
–
Screw in new needle holder.
–
Adjust the height of the needle holder (see chapter 2.5.4).
–
Tighten the screw 3.
–
Check the penetration of the needle into the needle hole.
–
Check lateral distance of the needle to the hook
(see chapter 2.5.5).
The exchange of the second needle holder is done likewise.
26
1
4
2
4
3
2
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...