Correction
–
Remove the throat plate.
–
Remove the needles from the needle holders.
Hint
For turning the needle holders one needle bar each has to be
disconnected.
–
Move the needle bars by handwheel nearly up to the top dead
centre.
–
Press down pawl 6 with a screwdriver and hold it pressed.
–
Turn handwheel again.
The pawl pressed down switches the needle bar off.
–
Release pawl 6.
–
Push the adjusting pin 4 into the needle holder as far as it will go.
–
Tighten the screw 7.
–
Place the measuring bridge 3 on the throat plate support.
–
Move the needle bar in looping stroke position and arrest it with the
locking peg.
It should be possible to push the measuring bridge under the
adjusting pin 4 with the smallest possible clearance.
–
Unscrew screw 8.
–
Set the height of needle holder 9 correspondingly.
For this purpose turn the needle holder. A complete rotation (360°)
is possible.
–
Align the needle holders.
The fronts of the needle holders must point to the front and be at
the same level.
–
Insert screw 8 in the needle holder and tighten.
–
Remove the locking peg and the adjusting pin.
–
Reconnect the needle bar.
For this purpose move the needle bar by handwheel above the top
dead centre (pawl 6 not actuated).
–
Adjust the second needle holder likewise.
31
6
8
7
9
5
4
3
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...
Страница 147: ...145 1 2 3 2 3 4 5 9 10 4 5 6 7 1 8 ...