![Duerkopp Adler 745-34 Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350095.webp)
12.
Folders and pick-up folders (working methods B, D, F)
12.1 Proper fastening
Caution: Danger of injury !
Switch off the main switch.
Remove and mount the folder only with the sewing unit switched off.
Standard
Folder 2 is positioned correctly when the fastening screw 1 pushes into
the insertion bore of pin 3.
Correction
–
Loosen screw 1.
–
Pull the folder 2 out.
–
Check whether the insertion bore of pin 3 points towards the
fastening screw 1.
–
Reinsert the folder and tighten with screw 1.
93
1
2
3
Содержание 745-34
Страница 58: ...56 7 6 7 4 3 1 9 3 8 5 4 2 1 ...
Страница 61: ...Correction Unscrew screws 7 and take off the covering cap 6 Set the toothed belt tension with nut 10 59 10 ...
Страница 100: ...98 257 5 mm 3 2 1 4 117 5 mm 1 3 10 11 9 8 7 6 3 5 12 ...
Страница 108: ...Notes 106 ...
Страница 128: ...13 9 Error elimination a b c d e 126 2 13 1 4 3 7 6 5 12 11 10 9 8 5 6 ...
Страница 147: ...145 1 2 3 2 3 4 5 9 10 4 5 6 7 1 8 ...