background image

1

TABLE OF CONTENTS

FEATURES

2

SPECIFICATIONS

2

INSTALLATION

3

Mounting the Panel ............................................................... 3

Mounting the Keypad ........................................................... 3

Auxiliary Power Connection .................................................. 3

PGM Terminal Connections .................................................. 3

Bell/Siren Connection ........................................................... 3

Keypad Wiring ...................................................................... 3

Fire Zone Wiring .................................................................... 3

Burglary Zone Wiring ............................................................ 3

Battery Connection ............................................................... 3

Telephone Line Wiring .......................................................... 3

GUIDELINES FOR LOCATING SMOKE DETECTORS 4

KEYPAD FUNCTIONS

5

Introduction ........................................................................... 5

Master Code ......................................................................... 5

2nd Master Code .................................................................. 5

Installer’s Programming Code .............................................. 5

Arming .................................................................................. 5

Auto-Bypass/Home-Away Arming ........................................ 5

Arming Without Entry Delay .................................................. 5

Disarming .............................................................................. 5

Zone Bypassing [

Q

]+[1] ....................................................... 5

Trouble Conditions [

Q

]+[2] ................................................... 5

Alarm Memory [

Q

]+[3] .......................................................... 6

Downloading Callup Command [

Q

]+[4] ............................... 6

User Programming Commands [

Q

]+[5] ............................... 6

EEPROM Reset ..................................................................... 6

User Function Commands [

Q

]+[6]+[Master Code] .............. 6

Utility Output Command

[

Q

]+[7] or  [

Q

]+[7]+[Access Code] ............................ 7

Installer’s Programming Command

[

Q

]+[8]+[Installer’s Code] ........................................... 7

Arming without Entry Delay [

Q

]+[9]+[Access Code] ........... 7

Arming For The Night [

Q

]+[1] ............................................... 7

Quick-Exit Command [

Q

]+[0] when armed .......................... 7

Quick-Arm Command [

Q

]+[0] .............................................. 7

Keypad Zones ...................................................................... 7

PROGRAMMING

8

How to Program .................................................................... 8

Program Data Review ........................................................... 8

Binary Data Display .............................................................. 8

HEX Data Programming ........................................................ 8

Programming Sections ......................................................... 8

[00] Binary Programming ................................................. 8

[01] 1st Phone Number .................................................... 8

[02] 1st Account Code ..................................................... 8

[03] 2nd Phone Number ................................................... 9

[04] 2nd Account Code .................................................... 9

[05] to [10] Reporting Codes ........................................... 9

[05] Zone Alarm Reporting Codes ................................... 9

[06]  Zone Restoral Reporting Codes .............................. 9

[07] Closing (Arming) Reporting Codes

Partial Closing Reporting Code ................................ 9

[08] Opening (Disarming) Reporting Codes

After Alarm Reporting Code ...................................... 9

[09] Priority Alarms and Restorals .................................... 9

[10] Maintenance Alarms and Restorals ........................ 10

[11] Zone Definitions ...................................................... 10

[12] 1st System Option Code ......................................... 11

[13] 2nd System Option Code ....................................... 11

[14] 3rd System Option Code ........................................ 11

[15] Communication Variables ....................................... 11

[16] Zone Bypass Mask ................................................. 11

[17] System Times .......................................................... 11

[18] Auxiliary Delay Loop Entry/Exit Times .................... 12

[19] System Clock Times ............................................... 12

[20] New Installer’s Code ............................................... 12

[21] New Master Code ................................................... 12

[22]  2nd Master Code ................................................... 12

[23]  Communication Formats ........................................ 12

[24] Programmable Output Options (PGM Terminal) .... 13

[25] Communicator Call Directions ................................ 13

[26] Downloading Telephone Number ........................... 13

[27] Downloading Access Code .................................... 13

[28] Panel Identification Code ........................................ 13

[29] Number of Rings Before Answering ....................... 13

[30] Reset to Factory Default ......................................... 13

[31] 4th System Option Code ......................................... 14

[32] 5th System Option Code ......................................... 14

[33] Answering Machine Double Call Timer .................. 14

[34] 6th System Option Code ......................................... 14

[35] LINKS1000 Test Reporting Code ........................... 14

[36] Keypad Lockout Control ......................................... 14

[90] Installer’s Lockout Enable ....................................... 14

[91] Installer’s Lockout Disable ...................................... 14

FOR THE RECORD

15

PROGRAMMING WORK SHEETS

16

LIMITED WARRANTY

inside front cover

INDUSTRY CANADA NOTICE

inside front cover

CONTROL PANEL WIRING DIAGRAM

inside back cover

Содержание PC1550

Страница 1: ...9 04 2nd Account Code 9 05 to 10 Reporting Codes 9 05 Zone Alarm Reporting Codes 9 06 Zone Restoral Reporting Codes 9 07 Closing Arming Reporting Codes Partial Closing Reporting Code 9 08 Opening Disa...

Страница 2: ...peration Download Upload capability Programmable auto downloading Swinger shutdown Transmission delay Six access codes Master key code All zones programmable as fire zones Programmable test transmissi...

Страница 3: ...witched AC source and close to the telephone line connection Remove the printed circuit board the mounting hardware and the keypad from the cardboard retainer inside the cabinet Before attaching the c...

Страница 4: ...fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the across the ceiling surface and begins to bank down from the across the ceiling surface and...

Страница 5: ...before going to bed and is useful for users who have a keypad outside areas protected by the interior zones Arming Without Entry Delay To eliminate Entry Delay arm the system using 9 access code An ex...

Страница 6: ...aster Code The installer may choose to not allow the user to program the Master Code section 13 option 2 The 6th code may be changed from a regular code into a One time Use code or Maid s Code section...

Страница 7: ...ammable section 14 option 5 for feedback 3 beeps or silent no buzzer feedback If programmed for audible the buzzer will sound once the key input is accepted keep time When the panel is powered up the...

Страница 8: ...mode For2 digitpairs bothdigitsmustbeprogrammed before pressing the key Only the data entered before pressing the key will be changed in the EEPROM Program Data Review Enter the section you wish to pr...

Страница 9: ...2 digit code 31 TRANSMISSION SENT 1234 31 3 1 FORMAT Extended reporting requires 3 digit Account Code in section 02 or 04 i e Enter 1230 for code 123 Format Code 8 9 A B C depending on receiver type i...

Страница 10: ...ny loop programmed for fire the Trouble light will come ON and the keypad sounder will beep every 10 seconds Thekeypadtroublebuzzerwillsoundandthe Trouble light will come ON regardless of whether the...

Страница 11: ...r zone definitions 2 Exit delay time 001 to 255 seconds This value determines the standard Exit Delay time The factory default exit time is 120 seconds For zone definitions see Section 11 3 Bell cut o...

Страница 12: ...the type of format which will be sent to each of the two telephone numbers programmed in section 01 and 03 For each telephone number enter one digit from the list below See the HEX data programming se...

Страница 13: ...he Exit Delay This option may be used to provide lighting in the exit area or to activate a device when the Exit Delay begins 0C LINKS1000 Interface This option configures the system for use with the...

Страница 14: ...Squawk during Entry Delay OFF No Bell Squawk during Entry Delay 6 ON F Key disabled OFF F Key enabled Factory default When Light 3 is ON Audible Exit Fault When the system is armed and a Standard Del...

Страница 15: ...__________________________________ ZONES Zone Type Protected Area 1 _____________________________ __________________________________________________________________ 2 _____________________________ ___...

Страница 16: ...Closing Arming Reporting Codes Partial Closing Reporting Code Page 9 Access Code 1 Access Code 4 Access Code 2 Access Code 5 Access Code 3 Access Code 6 Partial Closing Code 08 Opening Disarming Repo...

Страница 17: ...sistor loops ON Zone Light 6 Keypad P anic audible bell Keypad P anic silent bell 13 2nd System Option Code Page 11 Default Zone Light ON Zone Light OFF ON Zone Light 1 Call 1st phone only Backup to 2...

Страница 18: ...Light 6 17 System Times Page 11 Default Default 0 3 0 Entry Delay seconds 0 3 0 AC fail transmission delay minutes 1 2 0 Exit Delay seconds 0 5 0 Slow loop response time x 10 ms 0 0 4 Bell Cut off mi...

Страница 19: ...econds 7 08 Strobe Output latched alarm output 03 Utility Output Any Access Code 5 seconds 7 09 Failure to Communicate Output follows trouble 4 04 5 Second Reset Pulse 7 0A PGM ON during Entry Delay 0...

Страница 20: ...liary delay Auxiliary delay normal ON Zone Light 6 60 s bypass on power up Zones active on power up 33 Answering Machine Double Call Timer Page 14 Default 0 6 0 Valid entries are 001 to 249 34 6th Sys...

Страница 21: ...ay consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 The Load Number of this unit is 2 AVIS L tiquette de...

Страница 22: ...ds of the Entry Delay to warn that the Entry Delay is about to expire Zone Light 5 Bell Squawk During Entry Delay The bell siren will squawk during the Entry Delay If Zone Light 4 is on the bell siren...

Страница 23: ......

Страница 24: ...l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protec...

Отзывы: