AC Power Wiring
Complete all wiring to the control panel before connecting AC
power or the battery. Do not plug the transformer into an
outlet that is controlled by a switch.
Telephone Line Wiring
Do not connect the alarm panel communicator to telephone
lines intended for use with facsimile (fax) machines. These
lines may incorporate a voice filter which disconnects the
line if other than fax signals are detected. This may result
in incomplete transmissions from the alarm panel
communicator.
RED
BATTERY CHARGE CURRENT
IS 360 mA MAX
12 VOLT 4 Ah.
GEL - CELL
+
BATTERY CAPACITY FOR
EMERGENCY STANDBY
IS AT LEAST 4 HOURS IF
THE TOTAL LOAD (BELL
AUX OUTPUTS) IS 800 mA
OR LESS
BLK
-
Battery Connection
If the battery is reverse connected, the 5 A fuse will blow. The
battery charging voltage is factory set and normally needs no
adjustment. If the battery charging voltage is out of adjustment,
contact your service representative.
NOTE:
The PC1510 will not power up, even with a fully
charged battery, until AC power is connected. After an
extended AC power failure, the battery will be automatically
disconnected when its voltage drops to between 9 V and 10
V. This feature is designed to prevent damage to the battery
due to deep discharging.