24
PC1510 Version 4.1
[16]
Zone Bypass Mask
Page 14
If the zone light is ON, the zone can be bypassed using the [
∗
][1] command. If a zone is defined as a fire zone,
it cannot be bypassed.
Default
ON
Zone Light 1
ON
Zone Light 2
ON
Zone Light 3
ON
Zone Light 4
ON
Zone Light 5
ON
Zone Light 6
[17]
System Times
Page 14
Default
0 3 0
Entry Delay (seconds)
1 2 0
Exit Delay (seconds)
0 0 4
Bell Cut-off (minutes)
0 3 0
AC fail transmission delay (minutes)
0 5 0
Slow loop response time ( x 10 ms)
0 3 0
Test transmission cycle or auto download cycle time (days)
Valid entries are “001” to “255”.
Do not enter “000”.
Do not enter “000”.
Do not enter “000”.
Do not enter “000”.
Do not enter “000”.
[18]
Auxiliary Delay Loop Entry / Exit Times
Page 15
Default
0 4 5
Entry Time (seconds)
1 2 0
Exit Time (seconds)
Valid entries are “001” to “255”.
[19]
System Clock Times
Page 15
Default
9 9 9 9
Automatic Arming (time of day)
9 9 9 9
Test transmission or auto download (time of day)
Enter 4 digits - “00” to “23” hours; “00” to “59” minutes. If a feature is not used, leave at the default setting of “9999”.