Communicator Format Options, Section [021]
A 2-digit entry is required for each telephone number. Only one communicator format may be
programmed for each telephone number. The following communicator formats are available for
the dialer:
1. 10 or 20 bps Pulse
2. Contact ID
3. SIA
4. Pager
Each format is explained below.
Pulse Formats
Depending on the pulse format selected the panel will communicate using the following:
•
10 bps, 1400 Hz handshake
•
10 bps, 2300 Hz handshake
•
20 bps, 1400 Hz handshake
•
20 bps, 2300 Hz handshake
Obey the following when using the Pulse format:
•
The digit ‘0’ will send no pulses and is used as a filler.
•
Account numbers must be four digits. . If a 3-digit code is required, program the fourth
digit as ‘0’.
•
The digit ‘0’ is not used in this format—substitute with HEX digit ‘A’.
•
All reporting codes must be two digits. If a single-digit code is required, program the sec-
ond digit as ‘0’.
•
To prevent the panel from reporting an event, program the reporting code as [00] or [FF].
Contact ID
Contact ID is a specialized format that will communicate more information quickly using tones
rather than pulses.
When using Contact ID, obey the following:
•
Account numbers must be four digits.
•
The digit ‘0’ is not used in this format—substitute with HEX digit ‘A’.
•
All reporting codes must be two digits.
•
To prevent the panel from reporting an event, program the reporting code as [00] or [FF].
Contact ID Communicator Options [052] #3
If
Contact ID Uses Automatic Reporting Codes
is selected, the dialer will automatically
generate a reporting code for each event. These identifiers are listed in Appendix A. If the
reporting code [00] is programmed, no transmission will be sent.
If the
Contact ID uses Programmed Reporting Codes
option is selected, the dialer will
only communicate events for which valid reporting codes are programmed.
Consult the following table for clarification of this feature:
Reporting Code Entry
Programmed Reporting Codes
Automatic Reporting Codes
00
No Transmission
No Transmission
FF
No Transmission
Automatic reporting code sent
01-FE
01-FE sent
Automatic reporting code sent