English
GENERAL NOTES
Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that all
gas appliances are installed by competent persons in
accordance with the above regulations. Failure to install
appliances correctly could lead to prosecution.
The casing can be removed by lifting it and sliding it for-
wards.
The inside of the glass can be cleaned with a damp cloth
or with a non-abrasive detergent.
To remove the glass, unscrew the wing nuts.
A cracked or broken glass front should be replaced
before the heater is used again.
If a coal is broken or for any other reason no longer in
the correct position, it should be moved immediately.
NB:
The Confederation of Registered Gas
Installers, whose members are identified by the
emblem shown here, are all required to work to
the recognised standards.
Cleaning and Maintenance
The gas control valve should not be lubricated. Periodical
maintenance should be carried out by a registered
installer.You are recommended to free the heater of dust
before and occasionally during the heating season.Do not
use abrasives when cleaning the heater. Damage to the
casing varnish, caused by anything being put on the appli-
ance, is not covered by the guarantee.
NB:
When replacing the pilot light burner, the coupling
nut in the gas control block should first be tightened by
hand and then tightened a quarter-turn with an
open-ended spanner.
Discoloration of walls and ceiling
Brown discoloration is an annoying problem, which is dif-
ficult to solve. It can be caused by dust burning as a result
of poor ventilation, for example, or by cigarette smoke or
candles.
These problems can be avoided by ensuring that the
room the heater is in is properly ventilated. A good guide-
line for ventilation is:
New buildings
: 3.24 m
3
/ hour per m
2
floor
surface of the room.
Existing buildings
: 25.20 m
3
/ hour for a room.
Use candles and oil lamps as little as possible, keeping the
wick as short as possible.While they enhance the atmos-
phere, candles and oil lamps also cause the formation of
large quantities of unhealthy soot particles in your home.
Cigarette and cigar smoke contains tar, which upon heat-
ing will precipitate on cold or damp walls. If you have a
newly cemented chimney or have had any other recon-
structions / renovations done, you are advised to wait at
least 6 weeks before lighting your fire, to allow the walls,
floor and ceiling to dry out completely.
Lighting the heater for the first time
There can be an unpleasant smell when you light the
heater for the first time.This is caused by the varnish
evaporating and will disappear after a few hours.We
therefore advise you, on initial use, to heat the appliance
at the highest setting while ventilating the room it is
installed in well.
Extra protection
This heater meets the normal safety standards regarding
surface temperatures, but physical contact with heated
surfaces should be avoided where possible. An additional
guard is recommended to protect young children and eld-
erly, infirmed or handicapped people.
Disposal
When replacing or otherwise removing the appliance, it
should be disposed of in compliance with current regula-
tions.
Shut off the connecting tap with coupling before com-
mencing disassembly. Undo the coupling between the
connecting tap and the appliance.The whole appliance can
now be disassembled and removed.
GENERAL NOTES
✂
GU
ARANTEE REGISTRA
TION C
ARD
In or
der to r
egister y
our guarantee
,please complete and r
eturn this car
d(no stamp r
equir
ed)
Details of equipment:
Model:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial No
.:
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
T
ype of gas:
Natural Gas
❑
L.P
.G.
❑
(please tick).
Model an serial no
.a
re
to be f
ound on data badge inside heater
.
Customer
:
Installed b
y:
Name
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Name
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
Ad
dr
ess (of installation)
. . . . . . . . . . . . . . . . . . . . . .
A
d
d
ress
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
P
ost Code
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P
ost Code
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
Tel.
No
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tel.
No
.
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
Appliance installed in
. . . . . . . . . . .(Office
,Chur
ch,
etc
.)
Is a
ppliance r
eplacing alternativ
e fuel:
Solid Fuel
❑
Oil
❑
Electricity
❑
(please tick).
If r
eplacing existing balanced flue heater mak
e of original
Date of installation
N.B.
Wher
e mor
e than one a
ppliance installed,
please complete all car
ds and r
eturn in en
velope using fr
eepost ad
dr
ess on r
eser
ve
.
Completion of this car
d in no wa
y aff
ects y
our statutor
y rights
Thank y
ou DR
UGASAR
LIMITED