19
Depending on these variables to achieve a proper supply to the delivery point, it is always
necessary to ensure that the pipeline pressure loss plus the pressure required at the
lubrication point does not exceed the maximum pressure supplied for pump delivery
In the event of installation of
emergency stop control
, the logic chain that also includes the
MACHINE
must reach a reliability such to guarantee a minimum Performance Level equal to PL =
c, in accordance with UNI EN ISO 13849-1: 2016
Room with the following operational
environmental conditions
, necessary for correct
operation of the M
ACHINE
:
-
ambient temperature - 10°C ÷ + 50°C (+ 14°F ÷ + 122°F);
-
relative humidity 90%.
In the installation room,
there must be no gases or corrosive or harmful acids
, damaging both
to the operators and to the
MACHINE
itself.
In the installation room,
there must be no potentially explosive areas
generated by bases or
powders.
In the room where the machine is installed, a
brightness
must be guaranteed no lower than
300 lux, taking care for the uniformity of the lighting and the absence of reflections.
In the work room,
the following must not be present
:
-
strong oxidising agents (acids in general, oxidising mineral acids, amino compounds,
magnesium, aluminium and zinc salts);
-
open flames;
-
sparks;
-
heat sources;
-
abrasive powders.
4.2. Transport, handling and installation
DANGER:
the
M
ANUFACTURER
will not be held liable for any damage to objects and/or personnel
stemming from improper operations carried out by unqualified, untrained or
unauthorised personnel.
DANGER:
the
M
ANUFACTURER
will not be held liable for any damage to objects and/or personnel
stemming from improper operations carried out by unqualified, untrained or
unauthorised personnel.