rev 5.0 with software Ind1V022
3.4 Brake
controllers
3.4.1 REC12
Brake control unit REC12 is a line voltage half-wave rectifier for DC-brakes.
Voltage range
200...690Vac
Output voltage U
DC
Half wave 0.45 x U
AC
Maximum current 1.25Adc
L2
L1-1
L1-2
a
b
K7
Brake
K7
K7
REC
1
2
AC Line Voltage
K7
When the brake is opened, the brake contactor K7 connects two phases of mains voltage to terminals L1 and
L2. In addition, the brake contactor shorts terminals a and b thus making the DC-circuit.
To close the brake, the brake contactor disconnects the supply to terminals L1 and L2. The released brake
contactor also opens the brake coil DC-circuit, which speeds closing of the brake. The purpose of the varistor
there is overvoltage protection for K7 contacts and the brake coil.
3.4.2 ESD141
Brake control unit ESD141 is a line voltage full/half-wave rectifier for DC-brakes.
Voltage range
200...690Vac
Output voltage U
DC
Full wave 0.90 x U
AC
Half wave 0.45 x U
AC
Maximum current
1.25Adc continuous and 2.5Adc at ED5%
1
2
3
4
5
6
7
K7
K7
Set 0.3s
Brake
K7
K7
ESD141
AC Line Voltage
K7
When the brake is opened, the brake contactor K7 connects two phases of mains voltage to terminals 1, 2 and
3, which makes the device a full wave rectifier. The full wave mode is used to get the brake open fast. In
addition, the brake contactor shorts terminals 4 and 5 thus making the DC-circuit.
24/58
Drivecon Inc. reserves the right to alter or amend the above information without notice.