24
5)
Connect each of 5 colored wires to the corresponding terminal on upper tier of TM2.
Terminal
Color
FWD
Orange
SP1
Violet
SP3
Blue
RST
Yellow
SYN-
Brown
6)
Wire 120VAC input signals to detachable section of D61530 terminal strip 24VAC for
D61531 (TB1). Wire gauge is size 24AWG to 14AWG maximum. Only a single wire is
permitted in each terminal for wires larger than 18AWG.
7)
Replace cover.
8)
Should TB1 need to be removed from its mating socket, DO NOT pull on TB1 or the wires
attached to TB1. Damage to socket and connector may result. Pry apart where both halves
meet with a small flat blade screwdriver.
4.3.4 CONNECTION
Two directions (including first speed), 4 extra speeds, special functions, and reset can be controlled
directly from 120V AC control signals or 24VAC for D61531. The following chart defines the input
to output relationship.
D61530 120VAC Input
(D61531 24VAC)
Terminal TB1
Output Function
F
(1)
FORWARD command & first speed
R
(2)
REVERSE command & first speed
2
(3)
Second speed
3
(4)
Third speed
4
(5)
Fourth speed
5
(6)
Fifth speed
ACN(7)
120VAC neutral (24VAC neutral with D61531)
RLA (8)
Output relay N.O.
RLC (9)
Output relay common
RLB (10)
Output relay N.C.
The input terminal block (TB1) will accept 24AWG-14AWG wire maximum.