2.4Standard Drive Ratings
Model
CC-204
CC-207
CC-215
CC-222
CC-237
CC-255
CC-275
CC-2110
CC-2150
CC-2220
Motor Rating (KW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.2
15
22.4
Constant Torque Motor
Rating (HP)(2)
0.5
1
2
3
5
7.5
10
15
20
30
Constant Torque Rated
Current (A) (1)
3.1
4.5
7.5
10.5
17.5
26
35
52
70
105
Rated Output (KVA)
1.2
1.7
2.9
4.2
7
10.3
13.9
20
28
41.7
Weight (lbs)
4.8
4.8
4.8
12.1
12.8
20.7
22
42.9
47.3
49.5
Input Voltage
1/3 phase, 200-240VAC (+/- 10%), 50-60 Hz (+/- 5%)
3 phase, 200-240 VAC (+ / - 10%), 50/60 Hz (+ / - 5%)
Output Voltage
3 phase, 200-240 VAC
Model
CC-404
CC-407
CC-415
CC-422
CC-437
CC-455
CC-475
CC-4110
CC-4150
CC-4220
Motor Rating (KW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.2
15
22.4
Constant Torque Motor
Rating (HP)(2)
0.5
1
2
3
5
7.5
10
15
20
30
Constant Torque Rated
Current (A) (1)
1.5
2.3
3.8
5.2
8.8
13
17.5
26
35
52
Rated Output (KVA)
1.2
1.7
2.9
4.2
7
10.3
13.9
20
28
41.7
Weight (lbs.)
9.2
9.2
9.2
9.2
18.5
22
22
45.1
47.3
49.5
Input Voltage
3 phase, 380-460 VAC (+ / - 10%), 50/60 Hz (+ / - 5%)
Output Voltage
3 phase, 380-460 VAC
(1)
150% overload for 120 seconds
(2)
Horsepower and current ratings based on CMAA class A-D use for traverse or hoist
operation with a mechanical load brake. Consult Drivecon for other service classes. Always
choose inverters based on peak current draw of motor to be within the overload rating of the
drive.
Table 2.4a 230V Crane Commander Ratings
Table 2.4b 460V Crane Commander Ratings