61
Section 7
Setting and Adjustment
7.1
General Description of Settings and Adjustments
Inverter offers many specific adjustments and programming abilities. The adjustments are accessed
via digital operator (keypad) or remote control terminals (TM2 for 24VDC or TB1 on the D61530
for 120VAC inputs) (D61531 for 24VAC inputs). Choose the most suitable control mode to suit the
application.
Table 7.1 Select control and frequency command mode
)Q
)Q
Inverter is controlled by
Operation frequency is set by
Digital operator
Digital operator (Fn25)
Digital operator
Remote frequency command
Remote control terminal
(TM2)24VDC or (TB1) 120VAC
(24VAC)
Digital operator (Fn25)
Remote control terminal
(TM2)24VDC or (TB1) 120VAC
(24VAC)
Remote frequency command
1
2
Remote control terminal
(TM2)24VDC or (TB1) 120VAC
(24VAC)
1-5 distinct preset speeds
1
3
Remote control terminal
(TM2)24VDC or (TB1) 120VAC
(24VAC)
2 step infinitely variable
1
4
Remote control terminal
(TM2)24VDC or (TB1) 120VAC
(24VAC)
3 step infinitely variable
(1)
In digital operator control, FWD REV JOG and STOP commands are accessed by digital
operator.
(2)
In remote control operation, FWD REV and STOP are accessed by remote control
inputs (TM2 for 24VDC inputs or TB1 of D61530 for 120VAC inputs)(D61531 for 24VAC
inputs). Please refer to the interconnection diagram figure 3.1 and 3.2 on pages 11 and 12.
(3)
In digital operator frequency command, operation frequency is set by
Fn25
.
(4)
In remote frequency command, operation frequency is set by external analog signal,
10Kohm variable resistor, 5 preset speeds, or ramp and hold infinitely variable.
(5)
Fn11
codes 2, 3, 4 are only operational when
Fn11=0
(remote input mode)
NOTE:
that the following three functions are effective in remote control mode only.
1:
Fn3
:
Remote operation method select
2:
Fn14
:
Reset
3:
Fn16
:
Direct start prohibit