Vigor2862 Series User’s Guide
78
parameters according to the information provided by your
ISP.
Username – Type in the username provided by ISP in this
field.
Password – Type in the password provided by ISP in this field.
Service Name – Type a name representing serive used.
Separate Account for ADSL – In default, WAN1 supports
VDSL2/ADSL and uses the same PPPoE account and password
for connection. If required, you can configure another
account and password for ADSL connection by checking this
box. If it is checked, the system will ask you to type another
group of account and password additionally.
WAN Connection
Detection
Such function allows you to verify whether network
connection is alive or not through ARP Detect or Ping Detect.
Mode – Choose ARP Detect or Ping Detect for the system to
execute for WAN detection. If you choose Ping Detect as the
detection mode, you have to type required settings for the
following items.
Primary/Secondary Ping IP – If you choose Ping Detect as
detection mode, you have to type Primary or Secondary IP
address in this field for pinging.
Ping Gateway IP – If you choose Ping Detect as detection
mode, you also can enable this setting to use current WAN
gateway IP address for pinging.
With the IP address(es) pinging, Vigor router can check if
the WAN connection is on or off.
TTL (Time to Live) – Set TTL value of PING operation.
Ping Interval – Type the interval for the system to
execute the PING operation.
Ping Retry – Type the number of times that the system is
allowed to execute the PING operation before WAN
disconnection is judged.
MTU
It means Max Transmit Unit for packet.
Path MTU Discovery – It is used to detect the maximum MTU
size of a packet not to be segmented in specific transmit
path.
Click Path MTU Discovery to open the following dialog.
Path MTU to – Type the IP address as the specific
transmit path.
MTU size start from – Determine the starting point
value of the packet.
MTU reduce size by– It determines the decreasing size
of MTU value. For example, the number specified in
this field is “8”. The maximum MTU size is “1500”.
After clicking the “detect” button, the system will
Содержание Vigor2862 Series
Страница 1: ......
Страница 13: ...Vigor2862 Series User s Guide xiii Index 962...
Страница 14: ......
Страница 16: ......
Страница 80: ...Vigor2862 Series User s Guide 64...
Страница 189: ...Vigor2862 Series User s Guide 173...
Страница 255: ...Vigor2862 Series User s Guide 239...
Страница 302: ...Vigor2862 Series User s Guide 286 This page is left blank...
Страница 336: ...Vigor2862 Series User s Guide 320 This page is left blank...
Страница 525: ...Vigor2862 Series User s Guide 509...
Страница 530: ...Vigor2862 Series User s Guide 514...
Страница 601: ...Vigor2862 Series User s Guide 585...
Страница 613: ...Vigor2862 Series User s Guide 597...
Страница 712: ...Vigor2862 Series User s Guide 696...
Страница 746: ...Vigor2862 Series User s Guide 730...
Страница 753: ...Vigor2862 Series User s Guide 737...
Страница 757: ...Vigor2862 Series User s Guide 741...
Страница 759: ...Vigor2862 Series User s Guide 743 P Pa ar rt t X X T Te el ln ne et t C Co om mm ma an nd ds s...