![Draytek Vigor2862 Series Скачать руководство пользователя страница 821](http://html1.mh-extra.com/html/draytek/vigor2862-series/vigor2862-series_user-manual_2529139821.webp)
Vigor2862 Series User’s Guide
805
type).
0 - Subnet Address
1 - Single Address
2 - Any Address
3 - Range Address
Example:
Set Subnet Address => -s u 0 192.168.1.10 255.255.255.0
Set Single Address => -s u 1 192.168.1.10
Set Any Address => -s u 2
Set Range Address => -s u 3 192.168.1.10 192.168.1.15
–d u
<Address Type> <Start IP
Address> <End IP Address> |
<Address Mask>
It means to configure destination IP address including address type,
start IP address, end IP address and address mask.
u – It means “user defined”.
Address Type - Type the number (representing different address
type).
0 - Subnet Address
1 - Single Address
2 - Any Address
3 - Range Address
Example:
Set Subnet Address => -d u 0 192.168.1.10 255.255.255.0
Set Single Address => -d u 1 192.168.1.10
Set Any Address => -d u 2
Set Range Address => -d u 3 192.168.1.10 192.168.1.15
-d o:g <obj>
It means to specify destination IP object and IP group.
o – indicates “object”.
g – indicates “group”
<obj>– indicates index number of object or index number of group.
Available settings range from 1-192. For example, “-d g 1" means
the first destination IP group profile.
-S o:g <obj>
It means to specify Service Type object and IP group.
o – indicates “object”.
g – indicates “group”
<obj> – indicates index number of object or index number of group.
Available settings range from 1-96. For example, “-S 0 1" means the
first service type object profile.
-S u <protocol>
<source_port__value>
<destination_port_vale>
It means to configure advanced settings for Service Type, such as
protocol and port range.
u – it means “user defined”.
<protocol> – It means TCP(6),UDP(17), TCP/UDP(255).
<source_port__value> –
1 – Port OP, range is 0-3. 0:= =, 1:!=, 2:>, 3:<
3 – Port range of the Start Port Number, range is
1-65535.
5 – Port range of the End Port Number, range is 1-65535.
<destination_port_value>:
2 – Port OP, range is 0-3, 0:==, 1:!=, 2:>, 3:<
4 – Port range of the Start Port Number, range is
1-65535.
6 – Port range of the End Port Number, range is 1-65535.
-F
It means the Filter action you can specify.
0 –Pass Immediately,
1 – Block Immediately,
Содержание Vigor2862 Series
Страница 1: ......
Страница 13: ...Vigor2862 Series User s Guide xiii Index 962...
Страница 14: ......
Страница 16: ......
Страница 80: ...Vigor2862 Series User s Guide 64...
Страница 189: ...Vigor2862 Series User s Guide 173...
Страница 255: ...Vigor2862 Series User s Guide 239...
Страница 302: ...Vigor2862 Series User s Guide 286 This page is left blank...
Страница 336: ...Vigor2862 Series User s Guide 320 This page is left blank...
Страница 525: ...Vigor2862 Series User s Guide 509...
Страница 530: ...Vigor2862 Series User s Guide 514...
Страница 601: ...Vigor2862 Series User s Guide 585...
Страница 613: ...Vigor2862 Series User s Guide 597...
Страница 712: ...Vigor2862 Series User s Guide 696...
Страница 746: ...Vigor2862 Series User s Guide 730...
Страница 753: ...Vigor2862 Series User s Guide 737...
Страница 757: ...Vigor2862 Series User s Guide 741...
Страница 759: ...Vigor2862 Series User s Guide 743 P Pa ar rt t X X T Te el ln ne et t C Co om mm ma an nd ds s...