background image

Section 6 -

 Limit Adjustments

Figure 10

Figure 9

Section 6.1 - Standard Motors 

(Fig. 10)

Section 6.1.1 - "Down" Limit Adjustment 

(requires 

5/32

" (4 mm) hex key wrench)

To Reduce Screen Drop:

1. 

Raise screen surface approximately 1' 

(30 cm)

 above desired setting  

and turn off.

2. 

Turn DOWN 

(I)

 limit screw clockwise 

(3 screw turns = 

1/2

 roller revolution)

.

3. 

Test by lowering screen. Repeat steps 1 & 2 until desired position is 

reached.

To Increase Screen Drop:

1. 

Lower screen to down limit.

2. 

With down switch on, turn DOWN 

(I)

 limit screw counterclockwise  

(3 screw turns = 1/2 roller revolution) 

to increase drop.

3. 

Test by raising screen approximately 1' 

(30 cm)

 then down to new  

down limit.

4. 

Repeat steps 2 and 3 until desired position reached.

Section 6.1.2 - "Up" Limit Adjustment

If Screen Raises Too High:

1. 

Lower screen surface approx. 1' 

(30 cm)

 below desired setting and turn off.

2. 

Turn UP 

(II)

 limit screw clockwise  

(3 screw turns = 1/2 roller revolution).

3. 

Test by advancing screen up.

4.  

Repeat steps 1 through 3 until desired position is reached.

If Screen Needs to Raise Higher:

1.  

Lower screen surface approx. 1' 

(30 cm)

 below desired setting and turn off.

2.  

With UP switch on, turn UP 

(II)

 limit screw counterclockwise  

(3 screw turns = 

1/2

 roller revolution)

.

3.  

Repeat steps 1 and 2 until desired position is reached.

 CAUTION:

 DO NOT allow dowel to wrap over roller when operating screen!  

This could damage screen.

Please Note:

 Screen limits are  

factory set. Instructions below  

for minor adjustments only.  

Please check with Draper prior  

to resetting screen limits.

 CAUTION:

- Be sure all switches are in “off” 

position before adjusting limit 

switches.

- Be prepared to shut off manually 

while testing.

- Screen may be damaged by 

lowering it too far and  

exposing roller.

- Motor must be installed so that 

limit switches are pointed down.

White Socket—Up

Yellow Socket—Down

White Socket—Down

Yellow Socket—Up

White Socket—Down

Yellow Socket—Up

Waterfall Roll

Standard Roll

Motor

End

Audience

Side

Motor

End

Audience

Side

Reverse Roll

Motor

End

Back

Side

I

I

+

+

DOWN Limit (I)

Clockwise decreases 

down 

travel.

UP Limit (II)

Counterclockwise

increases 

up 

travel.

DOWN Limit

 

(I)

Clockwise 

decreases  

down

 travel.

UP Limit 

(II)

Counterclockwise 

increases 

up

 travel.

page 6 of 12

Acumen

™ 

E & V - 220V

Содержание Acumen E

Страница 1: ... LVC IV 9 Section 9 Tab Tension Adjustment Procedure 10 Section 10 Dimensions Tab Tensioned Surface Shown 11 BACK PAGE Wall Ceiling Bracket Dimensions for Mounting Wall Ceiling Mounting Brackets Electrical Knock outs Top and Back Extruded Aluminum Case Motor Wiring Access Panel Removable Fascia TOOLS REQUIRED POWER DRILL PENCIL TAPE MEASURE HARDWARE by others LEVEL HEX WRENCH 3 32 Draper Inc 411 S...

Страница 2: ...testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety features of the unit should never be disabled bypassed or overridden The system should not be operated until all safety features are properly an...

Страница 3: ...n the other end of the screen dowel 4 Lower screen surface down some and remove the gold brackets from the dowel Retighten the dowel screws 3 SCREEN DOWEL BACK VIEW Section 3 Removing Shipping Brackets Tab Tensioned Screens Only Screen should not be operated until after dowel shipping brackets are removed Please Note Before fully operating screen lower viewing surface enough to fully expose shippi...

Страница 4: ...Product is very heavy Installer must provide adequate attachment hardware and anchors as required Installer must also ensure that structure is of adequate strength 2 Ensure that mounting brackets are level 3 Slide all Bracket Locks to the center of case 4 Holding the case by the endcaps lift it up and over the cleats on the mounting brackets see Fig 5 Wall Bracket Mounting Channels are shown in Fi...

Страница 5: ...ee Fig 7 Wall Bracket Mounting Channels are shown in Fig 8 below 6 Once the case is settled on the mounting brackets slide the Bracket Locks to the center of each mounting bracket see Fig 8 and secure set screw on the lock Ceiling Brackets Secured to Ceiling Mounting Hardware by others NOTE It is the responsibility of the installer to select mounting hardware appropriate for the mounting surface S...

Страница 6: ...hed If Screen Needs to Raise Higher 1 Lower screen surface approx 1 30 cm below desired setting and turn off 2 With UP switch on turn UP II limit screw counterclockwise 3 screw turns 1 2 roller revolution 3 Repeat steps 1 and 2 until desired position is reached CAUTION DO NOT allow dowel to wrap over roller when operating screen This could damage screen Please Note Screen limits are factory set In...

Страница 7: ... To set viewing surface to alternate format position move viewing surface to desired position and press STOP button Hold STOP button for at least 3 seconds to record position Please Note Press and release UP button on switch to move screen to upper limit Press and release DOWN button to move screen to lower limit While motor is in motion press STOP button for less than 2 seconds to stop viewing su...

Страница 8: ...ommon to screen 230V AC Neutral Red to screen directional Brown to screen directional Yellow to 230V AC Hot Black to 230V AC Hot Green Yellow Ground Blue Common Brown Down Black Up Internal Screen Wiring Electrically Straight Data Cable to more LVC IV modules A maximum of six 6 LVC IV modules can be linked together N L1 GND Location of key operated 0n off switch if furnished IR Eye Input Low Volta...

Страница 9: ...Low Voltage High Voltage Remove Access Door Low Voltage Wire Figure 13 FUSE 3 15 AMP 250 VAC 5x20mm Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Electrically Straight Data Cable to more LVC IV modules A maximum of six 6 LVC IV modules can be linked together IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Dashed wiring by electrician Factory wiring Low voltage...

Страница 10: ... circumstances will not require field adjustment If wrinkles are observed however follow the adjustment procedure shown in Figure 9 Figure 14 PUSH TURN CLOCKWISE to INCREASE TENSION PUSH TURN COUNTER CLOCKWISE to RELEASE TENSION END OF DOWEL END OF DOWEL CAUTION Do not touch or bend surface page 10 of 12 Acumen E V 220V ...

Страница 11: ...457mm Max Case Length Varies 7 1 8 181mm Centered Ceiling Bracket ACUMEN 7 1 8 181 mm 5 7 8 149 mm 18 457mm Max 6 11 16 170mm 8 1 4 210mm 3 4 19mm 7 1 8 181mm 4 1 2 114mm 5 15 16 151mm AC End of Case Dimensions Shown with Ceiling Bracket page 11 of 12 Acumen E V 220V ...

Страница 12: ...3mm 19mm 3 89mm 3 9 16 90mm 2 70mm 4 15 16 125mm Mounting Hardware by others NOTE It is the responsibility of the installer to select mounting hardware appropriate f or the mounting surface Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc com 765 987 7999 800 238 7999 2020 All Rights Reserved FORM Acumen_E_V_220V_Inst20 ...

Отзывы: