Fixing the hand strap

Insert the smaller loop into the hole in the housing.

Thread the longer loop through the eyelet and pull through.

Symbols and readings

The breath alcohol value is measured in μg/100 ml. The result is displayed as

 

"ZERO"

PASS"

"ALERT" 

or 

"FAIL"

. For threshold limits see page 20.

Symbols

In these instructions for use several symbols are used corresponding to the messages

 

indicated on the display:

Battery symbol 

Indicates the battery charging status:

Full battery

Battery capacity 2/3

Battery capacity 1/3

Empty battery

009239

7

3_1

.eps

OK

Alcot

e

s

t 68

1

0

Содержание Alcotest 6810 GB

Страница 1: ...D Breath Alcohol Screening Device with Datamanagement ST 207 2004_sw_6810 eps Alcotest 6810 Alcotest 6810 GB Operator Instructions for Use...

Страница 2: ...10 Conditions 10 Requirements of the person to be tested 10 Further measurement 15 Removing the mouthpiece 15 Menu 16 Activation 16 Operation 16 Symbols on the display 17 Menu 17 Function 17 Quick me...

Страница 3: ...ories speci ed in the order list may be used Liability for proper function or damage The liability for the proper function of the instrument is irrevocably transferred to the owner or operator to the...

Страница 4: ...ough measurement of the breath alcohol concentration For mobile use with batteries Preparation Alcotest 6810 GB is supplied with standard calibration by the manufacturer The date of the last calibrati...

Страница 5: ...at s what Measuring instrument 1 Display 2 Menu button UP 3 OK button 4 Menu button DOWN MENU 5 Communication port 6 Indicating LED 7 Mouthpiece receptacle 00223973_1 eps OK Alcotest 6810 M 1 2 3 4 6...

Страница 6: ...l on the display indicates empty Gently press onto the lock of the battery compartment and remove cover Observe correct polarity when inserting the batteries Close battery cover Batteries to be used 2...

Страница 7: ...is measured in g 100 ml The result is displayed as ZERO PASS ALERT or FAIL For threshold limits see page 20 Symbols In these instructions for use several symbols are used corresponding to the message...

Страница 8: ...acing up press the mouthpiece into mouthpiece receptacle until you hear it click into place Note The symbols under the battery ap mean Attention Please con sult the user instructions Before changing b...

Страница 9: ...ed Switch off Unless the device is at READY you are unable to turn the device off Keep button pressed The instrument switches off after 2 seconds Automatic switch off The instrument switches automatic...

Страница 10: ...juice mouth sprays containing alcohol medicines can interfere with measurements Rinsing the mouth with water or non alcoholic drinks does not reduce this waiting period Before sampling the person to...

Страница 11: ...ess twice the button Subject age to select the subject age press twice the button and the button to confirm the subject age press twice the button Subject gender to select the subject gender press the...

Страница 12: ...g 100ml ALERT 35 g 100ml FAIL 36 g 100 ml FAIL 36 g 100 ml Set mode see page 18 As soon as the information is entered READY R AIR R MARINE or R RAIL is displayed and a short audible signal is given A...

Страница 13: ...Analyzing Test result After 5 to 25 seconds depending on the instrument temperature and the measured concen tration the measured value is shown on the display ZERO PASS or ALERT in ROAD mode only or...

Страница 14: ...fficers Identity press the button Up to 6 digits digit 1 and 2 alphanumeric digit 3 to 6 only numeric To enter a 5 digit code use Blank for digit one enter the code by pressing the button or the butto...

Страница 15: ...e sensor see Technical data on page 26 the display shows WAIT Removing the mouthpiece Push the mouthpiece out of the mouthpiece holder Dispose of the mouthpiece in accordance with local regulations No...

Страница 16: ...plete tests are not stored The main menu is accessible to instrument supervisors only Operation Select functions using and buttons The selected function is highlighted Activate the selected function b...

Страница 17: ...enu Return to next higher menu level Menu item with sub menu Open menu item Selected function Further items below the visible items Further items above the visible items Function Activated item Actual...

Страница 18: ...d and clearing has not been completed prior to the accuracy check being attempted If the Expired time screen appears then before an accuracy check can be performed The instruments memory must always b...

Страница 19: ...displayed together with the check value Set mode Enter Set mode item by using the button Change by pressing or and choose with button XXXX according to local settings Back by enter the Back to menu i...

Страница 20: ...100 mL 36 g 100 mL 36 AIR ZERO PASS FAIL FAIL FAIL ROAD ZERO PASS PASS ALERT FAIL MARINE ZERO PASS PASS ALERT FAIL RAIL ZERO PASS PASS ALERT FAIL alcohol indication ROAD AIR MARINE RAIL ZERO 4 g 100 m...

Страница 21: ...al waste in accordance with local waste disposal regulations For more information about suitable waste disposal companies please contact the local authorities for environmental protection Note In case...

Страница 22: ...e display indicates empty change the batteries Gently press onto the lock of the battery compartment and remove cover Remove used batteries and insert new ones consider correct polarity Close battery...

Страница 23: ...ulations for the disposal of electric and electronic appliances which have been de ned in the EU Directive 2002 96 EC and in national laws are effective from August 2005 and apply to this instrument C...

Страница 24: ...charged Replace batteries Insuf ent volume Subject not blowing hard or evenly enough Ask to blow harder and more evenly Fault in display Cause Remedy Calibration error Calibration not successful Calib...

Страница 25: ...ownload and clear datalogger Perform accuracy check Calibration overdue lockout in X days Calibration intervall expired Device is usea ble until graceperiode is expired Perform calibration by trained...

Страница 26: ...splay range Display range is identical to measuring range If the result is exceeding the measuring range the display will show three arrows as over ow indication Ambient conditions For operation 0 to...

Страница 27: ...ally 0 6 of meas value month Intervals before readiness for operation 1st measurement about 6 s after terminating a result of a previous test in range breath alcohol unit 25 g 100 mL 120 s 50 g 100 mL...

Страница 28: ...ry 1 piece 13 35 804 Rechargable battery NiMH 1 piece 18 90 092 Set rechargeable battery for rechargeable bat teries 83 18 565 Case for Alcotest 6810 GB 83 17 920 Leather pouch for Alcotest 6810 GB be...

Страница 29: ...in display 24 25 Further measurement 15 Hand strap 7 Intended use 4 Intervals before readiness for operation 27 Last cal date 18 Last tests 18 Liability 3 Maintenance 3 21 Maintenance intervals 21 Me...

Страница 30: ...ple conditions 26 Sensitivity drift 27 Set contrast 18 Set mode 18 19 Storage 21 Switching off 9 Switching on 9 Symbols 7 Symbols on the display 17 Technical data 26 Test result 13 transmitting statio...

Страница 31: ......

Страница 32: ...73 GA 4754 500 en Dr ger Safety AG Co KGaA 2nd edition August 2007 Subject to alteration Dr ger Safety AG Co KGaA Revalstra e 1 D 23560 L beck Germany Tel 49 451 8 82 0 Fax 49 451 8 82 20 80 www draeg...

Отзывы: