OM-HY/6G(CE) 37
Service Procedures
4. If the door has been reversed and the switch must be removed and replaced, refer to the top and left side panel removal
in Section DD and then remove the switch as above.
Z. Door Reversing Procedures
1. Turn off steamer power and allow steamer to cool.
2. To remove door, support door while removing hinge-to-steamer bolts.
3. Place door with hinge on a flat, clean table (or similar support), with the gasket facing up. Be careful not to scratch door
surface.
4. Note and record distance between lock nut and end of door locking pin (bullet). This information will be needed during
bullet installation described in Step 6.
5. Loosen lock nut with a wrench. Remove door locking pin and lock nut.
6. Coat bullet threads with NEVER-SEEZ high temperature compound. Install door locking pin and lock nut directly across
steamer cavity from old door locking pin location. Install these items so that lock nut-to-end of bullet distance is
approximately the same as measured in Step 4.
7. Remove the two truss head screws from above and below the old bullet location and install them above and below the
new bullet location.
8. Remove screws and U-channel from the door. Take the magnet and block assembly from present location and place it at
the opposite end of the door channel, with the magnet facing outward from the door.
9. Remove screws which secure the handle. Remove door handle from cam.
10. Apply NEVER-SEEZ high temperature (rated for 250ºC) anti-seize and lubricating compound to the cam and Locktite 242
to screw threads.
11. Turn handle and cam 180-degrees from their original positions and install them on the door with screws. Be sure handle
and cam move smoothly.
12. Be sure door handle is in the DOWN position. Turn U-channel 180-degrees from its original position, hold door spring in
U-channel open with a screwdriver or similar tool, and install U-channel. Do not install the screw at this time.
13. Check operation of the cam. Push up on the door handle and check if the spring opens. If the spring does not open, cam
and spring are NOT correctly aligned and problem must be corrected.
14. Apply a light amount of Locktite 242 to screws, then install screws securing U-channel.
15. Apply Locktite 242 to the hinge-to-steamer bolts, then install door and hinge mounting bolts. Do NOT tighten mounting
bolts at this time.
16. Align door to steamer. Refer to X, Alignment procedure.
IMPORTANT. When the door is reversed, the alternate door switch (installed at time of manufacture) must be connected to the
circuit.
17. From the right side access to the upper portion of the steamer, disconnect the two leads of the door switch.
AA. Door Gasket (P/N 094147)
1. To install, turn off steamer, and allow to cool.