OM-HY/6G(CE) 35
3. Unplug the two terminal wires from the capacitor. Remove the capacitor.
To Install New Capacitor:
NOTICE: Make sure that the correct capacitor is used, which is 3 mfd at 330 volt.
4. Make sure the capacitor is seated properly, then tighten the screw securing the capacitor to the mounting plate.
5. Plug terminal wires to the capacitor.
U. Steam Generator Ready Thermostat (P/N
This thermostat is attached to the cavity steam port.
1. Turn off power to the steamer.
2. Unplug the two wires from the thermostat.
3. Using a wrench, remove the thermostat.
4. To install a new thermostat, use a small amount of heat sink compound (1 drop), applied to bottom of thermostat. Seat
the thermostat on the steam port and connect.
5. Plug the thermostat into the wiring harness.
V. Steam Port (P/N
& Gasket (P/N
1. Shut off power to the steamer.
2. Remove the 1-1/8 inch steam hose by loosening the clamp around the hose and sliding it away from the steam port. Turn
and pull to loosen hose and remove from steam port.
3. With a wrench, remove the screws holding the thermostat to the steam port.
4. Cut and fold up aluminum foil insulation blanket to expose the two nuts which hold the steam port to the cavity wall
threaded studs.
5. With a wrench, remove the two nuts.
6. Remove the steam port.
To Install:
7. Put a small bead of silicone sealant in and around the groove in the steam port to seal any possible leaks, or use gasket
8. Install steam port on threaded studs. Secure with two nuts.
9. Fold down aluminum foil insulation blanket to original blanket position and repair cuts with aluminum foil duct tape.
10. Reinstall thermostat as described in T above.
11. Reinstall steam hose to steam port and install the clamp.
W. Cavity Steam Hose Assemblies (P/N
There are two hoses which connect the steam generators with their respective cavities. One for the top cavity and one for the
bottom cavity. If both hoses are to be replaced, replace them one at a time.
1. Shut off power to the steamer.
Service Procedures