Rack Monitor 8800E/8801E
Document: Installation Manual
Date:
24 August 2016
Version: B.1
Page 26 of 29
Document: H71342
6 Trouble shooting
Although Many events are displayed on the screen a there are always problems that cannot be measured
automatically. Read operation manual for operational related problems.
On all relay contacts and at the power inlet voltage terminal suppressors are placed to limit the surge voltage
and current as well as for absorbing energy. These Surge protecting devices protects the Rack input voltage
and relay contacts against surges generated by electromagnetic effects, such as lightning or electrostatic
discharge, over-voltages and high inductive loads. If such a device is overloaded it can explode during the
protection process. Consult OPW if this has happened.
Do
NOT
replace fuses if the reason of a blown fuse is unknown.
Caution
: When replacing the fuses, always make sure that you replace the fuse with original ones with
an equal stated value.
7 Procedure in case of an Error or Emergencies
Many events could happen when working or installing a Rack Monitor 8800E/8801E. Therefore a summary is
made of a few events and errors and the possible solutions.
Important is when personal infliction has occurred the local medical services are contacted immediately, the
OPW Fluid Transfer Group Europe BV
cannot being held responsible for none, late or erroneous medical
care.
When there is no personal infliction, but there is a high risk of explosions, fire or environmental disorders the
local authorities should and must be contacted before contacting the
OPW Fluid Transfer Group Europe
BV
.
Condition
Possible Cause
Solution
- Not all bolts can be applied to
mount the enclosure to its
designated position.
- Check whether the drill
pattern is right.
- Correct the hole pattern
- Check if the bolts are M8x65
- The Rack Monitor
8800E/8801E doesn’t turn ON
- The mains connector isn’t
connected.
- Connect the mains connector.
- Check if the main wiring is
connected according to the
installation instruction.
- Check if there is any power
available at the terminal of the
Rack Monitor 8800E/8801E.
- The fuses are broken.
- Replace the fuses for new ones.
- The door cannot being closed
- The hinges aren’t completely
straight in the enclosure.
- Open the door again, lift it and try
to put the hinges in straight.
- There is a cable between the
door and the back of the
enclosure.
- Remove the cable (bend it the
other way) and try to close the
door again.
- System goes directly into ‘NON
PERMISSIVE’
- The deadman switch is not
connected.
- Connect the cable according to
the installation manual.
- Connect a bypass cable between
pin 1 & 2 according to the
installation manual.
For all other possible inflictions/damages to the Rack Monitor 8800E/8801E, contact
OPW Fluid Transfer
Group Europe BV
and ask for assistance to obtain a safe and right use.