Attention
:
Installation must be performed by authorized and trained personnel only.
1.6 Safety precautions
Warning
:
Read & Understand this instruction before starting installation.
•
Equipment to be used for its designated purpose only.
•
Local regulations for installation have to be followed at any time.
•
Product flow may result in static electricity, earthing of the equipment is required.
•
OPW instructions must be followed for installation of any OPW Product at any time.
•
Make sure to use adequate personal protection at all time during the operation
,
Caution
:
Switch OFF mains power before making any connections
1.7 Installation Preparations
For safe and efficient transportation, Rack Monitor 8800E/8801E’s is packed in a box. Each shipment can
contain one or more boxes with fastening materials for assembly of the Rack Monitor 8800E/8801E. Also
optional accessories are packed in boxes.
When on arrival one decides to store the Rack Monitor 8800E/8801E for later use, keep the Rack Monitor
8800E/8801E into the initial box and store it into a dry warehouse (for details see chapter 1.3.3). Make sure
(before installation or storage) to check if the Rack Monitor 8800E/8801E is free from damages.
All Rack Monitor 8800E/8801E’s will have an unique identification by means of an unique serial number.
Bolts, nuts and washers for mounting of the Rack Monitor 8800E/8801E are included in the scope of supply.
Following requirements apply for these materials:
•
Bolt material minimum Stainless Steel class A2-70
•
Torque setting as per bolt class.
No special tools or equipment for installation of the Rack Monitor 8800E/8801E are required.
Make use of metric Allen Keys and metric wrenches to secure the nuts from rotating.
1.8 Installation Rack Monitor 8800E/8801E
Steps to mount the Rack Monitor 8800E/8801E:
•
Remove the Rack Monitor 8800E/8801E from the box and make sure it is free from damages,
•
Check if the Rack Monitor 8800E/8801E corresponds to the drawing in
Figure 2
.