Rack Monitor 8800E/8801E
Document: Installation Manual
Date:
24 August 2016
Version: B.1
Page 21 of 29
Document: H71342
Overall wiring top side
Figure 19
Finishing installation
•
Remove the corrosion protector from the seal and attach it to the door,
Caution
: - Make sure, before closing the enclosure, that the cables do not get stuck between the door
and the bottom side of the enclosure.
•
Close the door, make sure to press the hinges completely into the enclosure,
•
Connect all 12 bolts M8x25,
Warning
:
Do
not
leave any bolts out for a safe use.
•
Tighten the bolts with a minimum of 14.5 Nm and a maximum torque of 27.6 Nm,
•
Make sure that all earth cables are connected,
•
Energize the system,
Warning
:
Do not make modifications to the Rack Monitor 8800E/8801E for alternative mounting (with
exception of the mentioned method in Annex B - Modification Mounting Holes), when not making use of the
initial mounting holes in the Rack Monitor 8800E/8801E any guarantees will be declined.