7) Edit Video Wall Layout and Configure Alarms

See the 

Grass Valley web site

 for GV Orbit and MV-831 user 

manuals. Perform the following steps to check basic functionality 
for the video wall, setting an alarm, and GV Orbit network 
connection:

View MV-831 Settings: 

1. Run GV Orbit Client (v4.0 or 

later) on a PC. 

2.

Click 

RollCall Control Screen

 

and enter the new MV-831’s IP 
address. Click 

OK

.

The MV-831 RollCall control 
screens are opened in a tab.

3.

On the 

System - Setup

 

screen, take a note of the MV-831’s 
1G1 Interface 

IP address

 and 

RollCall Settings 

Domain ID

.

4.

Close the tab.

Pull Default Layout from New MV-831: 

5.

Click 

New Project

 and select 

Connected Multiviewer Project

”. 

6.

Browse 

into 

a new and empty PC 

folder, where project data will be 
stored

.

 Click 

Choose

. Click 

Next

.

A list of devices available to GV Orbit is shown.

7.

Select the MV-831 from the displayed list. Click 

OK

A login screen is shown.

8.

Enter username and password of the project 

(default = admin, admin). Click 

Login

The project data is pulled from the device and a 

Project 

Home

 screen is shown. 

GV Orbit Project 
Screen: 

9.

Click the 

Walls

 

icon and select a 
wall item in the 
drop-down list 
(e.g. 

Wall1

).

The wall is shown 
in 

Run

 mode.

10. Click the 

 icon 

to enter 

Design

 

mode. 

The icon turns blue 
and the 

Wall Editor

 

screen is shown.

Make a Visible Change to the Wall:

11. Click on a video wall tile, to select it. 

Tile Properties

 are shown on the right-hand side.   

12. Change property 

Preferences > Type

 to 

Analogue Clock

.

The selected tile changes to a round clock face.

13. Click

 Project > Save File

 in the main menu to save this 

change.

Enable ‘Video Input Lost’ Alarm:

14. Click 

Multiviewer > Input Alarms

 in the main menu. 

A dialog is shown with tabs. On the:

Input Tab -

  Set 

Selected Input

 to 

Input 1

.

Alarm Tab -

 Scroll down 

Select Alarm

 box and 

select 

Video Input Lost

. Select 

Alarm Enable

.

Input Tab -

  Click 

Copy All

.

15. Click 

OK

.   Click

 Project > Save File

.

Video Input Lost

 alarm is enabled on all MV-831’s 48-input 

multiviewer inputs.

 

Push Modified Project to the MV-831:

16. Click 

Project > Push

17. Ensure the project name is selected and click 

OK

.

The MV-831 adopts new wall layout: An analogue clock is shown.

Provoking a ‘Video Input Lost’ Alarm Warning:

18. Disconnect signal going to 48-input multiviewer Input 25. 

i.e. at the MV-831’s 

Router Video Input 1

 connector. 

Video loss is detected at the 48-input multiviewer input.

A slow-flashing, 

red rectangular border

 

appears around the corresponding video 
wall tile (tile 25).

Alarms may also be seen in the 

Network

 window and 

Alarm List

 

window:

19. Locate and expand the 

Network 

window’s MV-831 item.

20. Right-click on the 

red

 

Input 25 

item and select 

Alarm List

 in 

drop-down menu. 

An 

Alarm List 

summary

 

window 

shows the 48-input multiviewer’s 

Input 25 

status.

Thank you for purchasing a new 

MV-831 Integrated Multiviewer

 module. 

This Quick Setup Guide will help you get the module running as quickly as possible. 

An MV-831 module combines a router video input and output module with 

a 48-input multiviewer. One or more MV-831 modules fit into a Sirius 830 router, 

each replacing a Sirius 830 input module and adjacent output module.

Upon Receipt of your MV-831 Multiviewer:

The product is supplied in dedicated packaging provided by Grass Valley:

Do not accept it if delivered in inferior or unauthorized materials.

Unpack the MV-831 product carefully and check components against the packing list. 

If anything is incorrect, please notify your Grass Valley Partner or notify Grass Valley directly. 

(

https://www.grassvalley.com/contact/support/

).

Check all component items have not been damaged in transit, including the MV-831 front and rear modules.

If any damage has occurred, notify your Grass Valley Partner (or Grass Valley directly) and the carrier immediately. 

Have your order details ready.

Retain the original packing materials because they could be useful for future transporting or shipping.

The MV-831 User Manual can be downloaded from 

https://www.grassvalley.com/products/mv-831/

MV

-831

 Mod

u

le

MV-831

Integrated Multiviewer

Quick Setup Guide

Safety Information: 

Caution:

 MV-831 Multiviewer products should only be 

serviced by qualified service personnel.

Caution:

 Take anti-static precautions when handling 

MV-831 modules, or when inserting or removing the 
modules.

Warning: 

To reduce the risk of electric shock, do not 

expose this equipment to water or moisture.

Warning: 

The MV-831 can be equipped with optical 

outputs which contain low-power laser beams. 

Do not look into an optical output. Laser radiation can 
cause irreversible and permanent damage of eyesight.

Warning: 

Do not look at the end of an optical fiber to see if 

light is coming out. Use optical instrumentation.

Warning:

 Unused optical outputs should be covered, to 

prevent direct exposure to the laser beam.

Page 3

RMY3 MV-831QSG

6) 

Default Video Wall (Display Outputs 1 to 4)

A default video tile-grid is shown on head 

Display Outputs 1

 to 

4

. All 48 video signals monitored by the multiviewer are 

shown. And  ‘HH:MM:SS’ time and  ‘display output number’  are also shown.

HH:MM:SS

Output number

Multiviewer 
input number 

(

1

 to 

48

 total)

Figure 5 

Default Video Wall Layout

(Default monitoring: 

1

 to 

24

 router outputs; 

25

 to 

48

, router inputs.)