5
Material configuration
5.1
Presentation of the terminal block of the Industrial Interface
To have access to the Industrial Interface card, unscrew the two fixing screws of its
compartment housing at the rear of the printer.
Pass the connecting cable through one of the grommets and fix the wires to the corresponding
terminals (see Figure 1).
NOTE
The connecting cable shield used should be connected to the
periphery of the metallic stuffing box of the printer and the same
type of connection should be made on the computer.
Figure 1:
Wiring of the V24 connection on B1 terminal block
1
TTYOUT-
Photocoupler output
2
20 mA current loop
3
TTYIN-
Photocoupler input
Factory set
4
TTYIN+
5
-TXDOT
Transmit data
6
RTSOUT
Request to send
7
DTROUT
Data Terminal ready
8
-RXDIN
Receive data
RS232C link
9
CTSIN
Clear to send
10
DSRIN
Data send ready
11
DSR-
Photocoupler DSR input
12
DSR+
13
GND
0V
14
SPROG 2
15
COMSPROG
16
SPROG 1
17
COMRAZC 1
18
RAZC1
19
COMRAZC2
20
RAZC2
21
RESET-
22
RESET+
23
-DSR422-
24
-
25
RXD422-
26
27
RXC422-
28
29
VALID422-
30
V
31
-DTR422-
32
-
33
TXD422-
34
35
TXC422-
36
37
GND
38
+ 5 V
39
+ 15 V
40
- 15 V
General
A13862 Version E
Page 2-5