Sequence to be programmed:
Identifier
0Ah
Transmission of message contents outside of lib.
Length
00h, 52h
82 bytes
Number of jet
01h
Jet no 1
Start of line delimiter
0Ah
Line 1
Bolderization
01h
Bolderization 1
Symbol generator
A0h
SIN7H118 (no 160)
Tab delimiter
1Eh
Start tab
Number of rasters
12h
18 rasters
Block 1, line 1
Tab delimiter
1Eh
End tab
Text
A... COMPANY
28 ASCII characters
Tab delimiter
1Eh
Start tab
Number of rasters
3Ch
60 rasters
Tab delimiter
1Eh
End tab
Start of line delimiter
0Ah
Line 2
Bolderization
02h
Bolderization 2
Symbol generator
38h
SIN16119 (no 56)
Block 1, line 2
Text
IMAJE
6 ASCII characters
Bolderization
01h
Bolderization 1
Symbol generator
53h
SIN05116 (no 83)
Block 2, line 2
Text
BOURG ...
17 ASCII characters
Start of line delimiter
0Ah
Line 3
Bolderization
02h
Bolderization 2
Symbol generator
54h
SIN05116 (no 84)
Tab delimiter
1Eh
Start tab
Number of rasters
90h
144 rasters
Tab delimiter
1Eh
End tab
Text
FRANCE
6 ASCII characters
Block 1, line 3
Tab delimiter
1Eh
Start tab
Number of rasters
1Eh
30 rasters
Tab delimiter
1Eh
End tab
End delimiter
0Dh
End of message
Checksum
3Bh
Check byte
Appendix
A13862 Version E