Detail of the data bytes
• Byte of the ELV of the CE:
State 0 = Closed
State 1 = Open
NOTE
On S4SI and S4SI Plus, all these solenoid valves are used.
On the other printers in the Jaime 1000 range, only the Additive and
Visco. solenoid valves are used.
• Levels byte:
State 0 = Level attained
State 1 = Level not attained
• Viscosity byte:
The value represents the filling time of the viscometer in seconds, in hexadecimal coding.
• Visco reference byte:
Visco reference time in seconds, in hexadecimal coding.
• Additives byte:
Number of additions in hexadecimal coding.
Visco
Equi-air
Equivisc
Additive
Ink
Load
Ink trans.
Air trans.
Recup. medium
Ink high
Accu. high
Accu. low
Recup. high
Visco low
Visco high
Ink low
Protocol
A13862 Version E
Page 5-35