Version with air cap GL and 4.0 mm
nozzle
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Protective gloves
Disassembling
Fig. 14: Disassemble needle and nozzle.
1. Thread off and remove set screw (4).
2. Remove bearing and needle spring (3).
3. Loosen cap nut (1).
4. Remove the air cap (1).
5. Unscrew nozzle (2) using monkey wrench
and remove.
Fig. 15: Disassembling Needle
6. Secure needle (6) on the wrench mount
in the center of the spray gun using the
monkey wrench before twisting.
7. Loosen the needle tip (5) using an instal-
lation wrench.
8. Push trigger through.
ð
The needle (6) is pushed a little back-
wards and out from the housing.
9. Remove needle (6).
10. Replace worn out or defective compo-
nents.
Assembling
11. Push in needle (6) carefully into the
housing.
12. Secure needle (6) on the wrench mount
in the center of the spray gun using the
monkey wrench before twisting.
13. Insert needle tip (5). Tighten using the
installation wrench.
14. Insert and tighten nozzle (2).
Tightening torque: 10 Nm
15. Place the air cap (1).
16. Tighten cap nut (1).
Faults
05/2018
EcoGun 116 - MSG00017EN
22/44