NOTICE!
Unsuitable cleaning agents
Unsuitable cleaning agents can damage
the product.
– Only use cleaning agents approved by
the material manufacturer.
– Follow safety data sheets.
– Place heavily soiled components in a
cleaning bath.
– Only place those parts in the
cleaning bath, which are suitable for
the cleaning bath.
– Use only electrically conductive
containers.
– Ground the container.
– Do not use ultrasound baths.
Use alcohols (isopropanol, butanol) for
non-flammable coating materials.
Remove dried non-flammable coating
materials using a material manufacturer-
approved organic thinner.
When cleaning with flammable detergent,
do not spray into a closed container. An
explosive gas-air mixture can form inside
closed containers.
NOTICE!
Damage due to unsuitable cleaning
tools
Unsuitable cleaning tools can damage the
product.
– Only use cloths, soft brushes and
paintbrushes.
– Do not use abrasive cleaning tools.
– Do not poke blocked nozzles with met-
allic objects.
– Do not use compressed air for
cleaning.
– Do not use any thinner spray guns.
– Do not use high pressure for cleaning
agents.
7.2
Cleaning
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Eye protection
Respiratory protection device
Protective workwear
Protective gloves
2. Disconnect the air hose from the spray
gun.
3. Remove feed cup.
4. Remove material residues with a cloth or
a soft brush.
5. Clean the spray gun carefully and dry it
with a soft cloth.
Clean filter of the flow cup.
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Protective gloves
Depending on the configuration, the spray
gun is supplied with a filter.
Cleaning and maintenance
05/2018
EcoGun 116 - MSG00017EN