11. Insert and tighten nozzle (2).
Tightening torque: 10 Nm
12. Release trigger lever (3).
13. Place the air cap (1).
14. Tighten cap nut (1).
7.3
Maintenance
7.3.1 Maintenance schedule
The maintenance intervals given below are based on experiential values. Adjust maintenance
intervals individually to increased requirements.
Interval
Maintenance work
After each use
Daily
Check state and tightness of the spray gun as well as of the connections
and lines.
Weekly
Lubricate lever bearing
7.3.2 Lubrication
The following components must be lubri-
cated with a silicone-free grease:
O-rings and seals
Bearing
Set screw and threads
Needle gland
Lever bearing
Lubricate internal components at the
time of maintenance work, which
include disassembly of the con-
cerned components any way.
Recommended lubricant: SYN-
8
Faults
8.1
Safety recommendations
NOTICE!
Property damage due to improper
replacement of needle and nozzle
Replacing only the needle or only the
nozzle could damage spray gun compo-
nents. This can compromise the tightness
of the spray gun. The spray pattern deteri-
orates.
– Observe order of replacement steps
(needle – nozzle).
– Observe order of assembly steps
(nozzle – needle).
– Always replace nozzle and needle at
the same time.
Faults
05/2018
EcoGun 116 - MSG00017EN
17/44