![Doosan NHP10-425WCU-EU-FX-T3 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/doosan/nhp10-425wcu-eu-fx-t3/nhp10-425wcu-eu-fx-t3_operation-and-maintenance-manual_2521365064.webp)
Operating & Maintenance Manual
Fault Finding
60
Fault Finding Chart
Bold Headings depict the COMPLAINT - Subheadings suggest the CAUSE
NOTE: Subheadings suggest sequence to follow troubleshooting.
1. Unit Shutdown:
Corrective Action
Out of Fuel
Add CLEAN diesel Fuel
Compressor Oil Temp. Too High
See Complaint 10
Engine Water Temp. Too High
Check coolant level. If necessary, Add.
Engine Oil Pressure Too Low
See Complaint 3 and Complaint 4.
Broken Engine Fan Belt
Replace fan belt.
Loose Wire Connection
Wiggle wires at switches & connector blocks. Make repairs.
Low Fuel Level Shutdown
Replace fuel sender.
Defective Sensor
Replace sensor.
Malfunctioning Relay
Replace relay.
Blown Fuse
Replace fuse.
Engine Malfunctioning
See Trouble Shooting in Engine Manual.
*Airend Malfunctioning
See Complaint 10.
2. Won’t Start/Run:
Low Battery Voltage
Check electrolyte level. Check connections.
Blown Fuse
Replace fuse.
Blown Fuse Malfunctioning Start Switch Replace switch.
Clogged Fuel Filters
Service filters. See Engine Operator’s Manual.
Out of Fuel
Add CLEAN fuel.
Compressor Oil Temp. Too High
See Complaint 10.
Engine Water Temp. Too High
Check fluid level. If necessary, Add.
Engine Oil Pressure Too Low
See Complaint 3 and Complaint 4.
Loose Wire Connection
Repair or replace connection.
Defective Sensor
Replace sensor.
Malfunctioning Relay
Replace relay.
Engine Malfunctioning
See Trouble Shooting in Engine Manual.
Airend Malfunctioning
See Complaint 10.
3. High Engine Temperature:
Broken Engine Fan Belt
Replace fan belt set.
*Ambient Temp. >120°F
Above spec limit.
Dirty Operating Conditions
Move unit to cleaner environment.
Dirty Cooler
Clean exterior of cooler.
*Out of Level >5 degrees
Relocate or reposition unit.
Operating Pressure Too High
Reduce pressure to spec.
Recirculation of Cooling Air
Close side doors.
Loose Wire Connection
Repair or replace.
Side Doors Open (no CAC cooling air)
Close Doors
* : > = greater than, < = less than
4. Low Engine Oil Pressure:
Low Oil Level
Add oil.
Out of Level >15 degrees
Relocate or reposition.
Wrong Lube Oil
See Engine Oil Spec. Change oil.
Clogged Oil Filter Element(s)
Replace element(s).
Engine Malfunctioning
See Trouble Shooting in Engine Manual.
Содержание NHP10-425WCU-EU-FX-T3
Страница 2: ...2...
Страница 4: ...2...
Страница 7: ...3 TABLE OF CONTENTS Operation Maintenance Manual TITLE PAGE SYSTEM DIAGRAMS 73...
Страница 8: ...4...
Страница 9: ...5 Foreword...
Страница 13: ...9 Safety...
Страница 21: ...17 General Information...
Страница 24: ...20...
Страница 25: ...21 Operating Instructions...
Страница 43: ...39 Maintenance...
Страница 56: ...52...
Страница 57: ...53 Lubrication...
Страница 60: ...56...
Страница 61: ...57 Fault Finding...
Страница 68: ...64...
Страница 69: ...65 Electrical...
Страница 73: ...Electrical Operating Maintenance Manual 69 Electronic Control Systems...
Страница 74: ...Always use Ingersoll Rand Replacement parts 70...
Страница 75: ...Electrical Operating Maintenance Manual 71...
Страница 77: ...73 System Diagrams...