OP000756
4-79
Inspection, Maintenance and Adjustment
Fan Motor Pressure and Fan rpm
The motor intergrates a proportional pressure relief valve, the
fan speed (and thus the cooling performance) can be infinitely
controlled depending on two different simultaneous input signals
from temperature sensors.
The cooling fan controller processes the two input signals and
controls the valve coil current. The proportional relief valve has a
fail safe characteristic, this means, max. relief valve setting is
adjusted automatically if the voltage supply is interrupted (e.g.
broken wire). This results in a max. fan speed and therefore in a
max. cooling performance.
Fan Motor Pressure
Standard
160 ± 5 bar (Speed Control)
136 ± 5 bar (Without Speed Control)
Fan rpm
500 ~ 1,800 (Speed Control)
1,800 (Without Speed Control)
7
8
4
3
2
9
1
6
5
FG001746
Figure 118
Reference
Number
Description
1
Engine
2
Cooling Pump
3
Cooler
4
Cooling Fan Controller
5
Fan Motor
6
Cooling Fan
7
Temperature Sensor (T/M Oil)
8
Temperature Sensor
(Coolant Water)
9
Transmission
Reference
Number
Description
Содержание DL160
Страница 2: ......
Страница 3: ...K1040196E I I Presentation 1Presentation PRESENTATION FG013087 Figure 1 ...
Страница 12: ...K1040196E Table of Contents IV ...
Страница 17: ...OP000753 1 5 Safety FG013042 1 3 10 12 6 4 11 5 9 8 3 7 10 4 6 2 Figure 1 ...
Страница 60: ...OP000753 Safety 1 48 ...
Страница 103: ...OP000754 2 43 Operating Controls CD Player Optional AST DIR FG000109 Figure 90 ...
Страница 216: ...OP000756 Inspection Maintenance and Adjustment 4 86 ...
Страница 226: ...OP000040 Troubleshooting 6 8 ...